Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2UZ-FE STARTING

2UZ-FE STARTING > SERVICE DATA



Starter
(1.4 kW type)
Rated voltage and output power
12 V 1.4 kW
No-load characteristics
Current
90 A or less at 11.5 V
Brush length
Standard
15.5 mm (0.610 in.)
Minimum
10.0 mm (0.394 in.)
Spring installed load
Standard
17.6 to 23.5 N (1.8 to 2.4 kgf, 4.0 to 5.3 lbf)
Minimum
11.8 N (1.20 kgf, 2.7 lbf)
Commutator
Diameter
Standard
30.0 mm (1.181 in.)
Minimum
29.0 mm (1.142 in.)
Undercut depth
Standard
0.6 mm (0.024 in.)
Minimum
0.2 mm (0.008 in.)
Circle runout
Maximum
0.05 mm (0.0020 in.)
Starter
(2.0 kW type)
Rated voltage and output power
12 V 2.0 kW
No-load characteristics
Current
100 A or less at 11.5 V
Brush length
Standard
15.0 mm (0.591 in.)
Minimum
9.0 mm (0.354 in.)
Spring installed load
Standard
21.5 to 27.5 N (2.2 to 2.8 kgf, 4.8 to 6.2 lbf)
Minimum
12.7 N (1.3 kgf, 2.9 lbf)
Commutator
Diameter
Standard
35.0 mm (1.378 in.)
Minimum
34.0 mm (1.339 in.)
Undercut depth
Standard
0.7 mm (0.028 in.)
Minimum
0.2 mm (0.008 in.)
Circle runout
Maximum
0.05 mm (0.0020 in.)
Field frame
Shunt coil resistance
at 20°C (68°F)
1.5 to 1.9 Ω