EMISSION CONTROL SYSTEM > DETAILS |
| FUNCTION OF MAIN COMPONENTS |
The main components of the exhaust emission control system are as follows:
| Component | Function |
| TWC | Oxidizes CO and HC in the exhaust gas and deoxidizes NOx at the same time, to purify them into CO2, H2O and N2. |
| Heated Oxygen Sensor | The signal of the air fuel ratio sensor changes abruptly between lean and rich at the stoichiometric air fuel ratio. Located downstream of the catalytic converter. For details see the 1GR-FE Engine Control. |
| Air fuel Ratio Sensor | Is used to determine the concentration of oxygen remaining in the exhaust gas. Has a characteristic where its output is proportional to the engine air fuel ratio. Located upstream of the catalytic converter. For details see the 1GR-FE Engine Control. |
| ECM | Controls the volume of fuel consumed based primarily on the signal from the air-fuel ratio sensor, with minor corrections based on the signal from the heated oxygen sensor. This control optimizes the exhaust emissions. |
The main components of the evaporative emission control system are as follows:
| Component | Function | |
| Charcoal Canister Assembly | Contains activated charcoal to absorb the fuel vapor that is created in the fuel tank assembly. | |
| Restrictor Passage | Prevents a large amount of vacuum during purge operation or system monitoring operation from affecting the pressure in the fuel tank assembly. | |
| Fresh Air Line | Fresh air goes into the charcoal canister assembly and the cleaned drain air goes out into the atmosphere. | |
| Canister Pump Module | Vent Valve | Opens and closes the fresh air line in accordance with signals from the ECM. |
| Leak Detection Pump | Applies vacuum to the evaporative emission system in accordance with signals from the ECM. | |
| Canister Pressure Sensor | Detects the pressure in the evaporative emission system and sends the signals to the ECM. | |
| Purge VSV | Opens in accordance with the signals from the ECM when the system is purging, in order to send the fuel vapor that was absorbed by the charcoal canister assembly into the intake manifold. In system monitoring mode, this valve controls the introduction of vacuum into the fuel tank assembly. | |
| Canister Filter | Prevents dust and debris in the fresh air from entering the system. | |
| ECM | Controls the canister pump module and the purge VSV in accordance with the signals from various sensors, in order to achieve a purge volume that suits the driving conditions. In addition, the ECM monitors the system for any leak and stores a DTC if a malfunction is found. | |
The main components of the air injection system are as follows:
| Component | Function |
| Air Pump Assembly | Uses a built-in DC motor to supply air to the emission control valve set. |
| Emission Control Valve Set | Introduces air that is pumped by the electric air pump into the exhaust manifold. |
| Air Injection Control Driver |
|
| ECM |
|
| OPERATING CONDITION |
The following are the typical conditions necessary to enable an evaporative emission leak check:
| Typical Enabling Conditions |
|
| SYSTEM CONTROL |
Purge Flow Control
When the engine has reached a predetermined state (closed loop, engine coolant temperature above 80°C (176°F), etc.), stored fuel vapor is purged from the charcoal canister assembly whenever the purge VSV is opened by the ECM.
The ECM will change the duty ratio cycle of the purge VSV, thus controlling purge flow volume. Purge flow volume is determined by intake manifold pressure and the duty ratio cycle of the purge VSV. Atmospheric pressure is allowed into the charcoal canister assembly to ensure that purge flow is constantly maintained whenever purge vacuum is applied to the charcoal canister assembly.

Onboard Refueling Vapor Recovery (ORVR)
When the internal pressure of the fuel tank assembly increases during refueling, the fuel vapor enters the charcoal canister assembly. The air that has had the fuel vapor removed from it will be discharged through the fresh air line. The vent valve is used to open and close the fresh air line, and it is always open (even when the engine is stopped) except when the vehicle is in monitoring mode (the valve will remain open as long as the vehicle is not in monitoring mode). If the vehicle is refueled in system monitoring mode, the ECM will recognize the refueling by way of the pressure sensor, which will detect the sudden pressure increase in the fuel tank assembly, and the ECM will open the vent valve.

EVAP Leak Check
The EVAP leak check operates in accordance with the following timing chart:

| Order | Operation | Description | Time |
| 1) | Atmospheric Pressure Measurement | The ECM turns the vent valve off (vent) and measures EVAP system pressure to determine the atmospheric pressure. | 60 sec. |
| 2) | 0.02 in. Leak Pressure Measurement | The leak detection pump creates negative pressure (vacuum), limited by a 0.02 in. orifice and the pressure is measured. The ECM determines this as the 0.02 in. leak pressure (reference pressure). | 360 sec. |
| 3) | EVAP Leak Check | The leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized pressure is larger than the 0.02 in. leak pressure, ECM determines that the EVAP system has a leak. If the EVAP pressure does not stabilize within 15 minutes, the ECM cancels the EVAP monitor. | Within 15 min. |
| 4) | Purge VSV Monitor | The ECM opens the purge VSV and measures the EVAP pressure increase. If the increase is large, the ECM interprets this as normal. | 10 sec. |
| 5) | Repeat 0.02 in. Leak Pressure Measurement | The leak detection pump creates negative pressure (vacuum) limited by a 0.02 in. orifice and the pressure is measured. The ECM determines this as the 0.02 in. leak pressure. | 20 sec. |
| 6) | Final Check | The ECM measures the atmospheric pressure and records the monitor result. | - |
| FUNCTION |
Air Injection System
To ensure the proper warm-up performance of the Three-Way Catalytic converters (TWCs) after starting a cold engine, an air injection system is used.
This system is comprised of an air injection control driver, an air pump assembly, and 2 emission control valve sets with built-in air pressure sensors.
The emission control valve sets provided on each bank are controlled independently by the ECM and the air injection control driver.
The ECM estimates the amount of air injected to the TWCs based on signals from the mass air flow meter in order to regulate the air injection time.
| CONSTRUCTION |
Three-Way Catalytic converter (TWC)
2 TWCs have been provided for the front exhaust pipe assembly.
Ultra thin-wall high-cell density ceramic type TWCs are used.
This TWC enables improved exhaust emissions by optimizing the cell density and the wall thickness.

| *1 | Exhaust Manifold Sub-assembly - TWC | *2 | TWC |
| *a | Ultra Thin-wall | - | - |
Fuel Inlet (Fresh Air Inlet)
The fresh air line inlet is located the near the fuel inlet pipe opening. The fresh air from the atmosphere and drain air cleaned by the charcoal canister assembly will go in or out of the system through the passages shown below.

| *1 | Fuel Tank Cap | *2 | Canister Filter |
| *3 | Fuel Inlet Pipe | - | - |
| *a | Fresh Air | *b | Cleaned Drain Air |
| *c | To Charcoal Canister Assembly | - | - |
Charcoal Canister
Contains activated charcoal to absorb the fuel vapor that is created in the fuel tank assembly.

| *1 | Charcoal Canister | *2 | Purge Port (To Intake Manifold) |
| *3 | EVAP Port (From Fuel Tank) | *4 | Canister Pump Module |
| *5 | Fresh Air Port | - | - |
Canister Pump Module
The canister pump module consists of the vent valve, reference orifice, canister pressure sensor, leak detection pump and pump motor.
The vent valve switches the passages in accordance with the signals received from the ECM.
A DC type brushless motor is used for the pump motor.

| *1 | Vent Valve | *2 | Reference Orifice |
| *3 | Canister Pressure Sensor | *4 | Leak Detection Pump |
| *5 | Pump Motor | - | - |
| *a | Canister Pump Module Cross Section | - | - |
![]() | Fresh Air | ![]() | Charcoal Canister Assembly |

Air Pump Assembly
The air pump assembly consists of a DC motor, an impeller, an air filter and a heater.
The DC motor is controlled by the air injection driver in accordance with signals from the ECM. The motor supplies air into an emission control valve set through the impeller.
A heater is provided to prevent operation faults in cold conditions.

| *1 | Impeller | *2 | Heater |
| *3 | DC Motor | - | - |
| *a | Cross Section | - | - |
![]() | To Emission Control Valve Set | ![]() | From Air Inlet |
Emission Control Valve Set
The emission control valve set consists of an air switching valve that switches the air flow and a reed valve that restricts the exhaust flow to one direction.
The air switching valve is a solenoid valve that is actuated by the ECM and air injection control driver.
The air pressure sensor is built into the corresponding emission control valve set.
The emission control valve sets for bank 1 and bank 2 have the same basic structure and function.

| *1 | Emission Control Valve Set (Bank 1) | *2 | Emission Control Valve Set (Bank 2) |
| *3 | Air Switching Valve | *4 | Air Pressure Sensor |
| *a | Emission Control Valve Set (Bank 1) Cross Section | - | - |
![]() | Air In | ![]() | Air Out |
Air Pressure Sensor
The air pressure sensor consists of a semiconductor, which has a silicon chip that changes its electrical resistance when pressure is applied to it. The sensor converts the pressure into an electrical signal, and sends it to the ECM in an amplified form.
The air pressure sensors for bank 1 and bank 2 have the same basic structure and function.

| OPERATION |
Evaporative Emission Control System
When the engine switch is turned off, the purge VSV and the vent valve are turned off. Therefore, atmospheric pressure is introduced into the charcoal canister assembly.
The ECM measures the atmospheric pressure using the canister pressure sensor.
If the measured atmospheric pressure is out of range, the ECM actuates the leak detection pump in order to monitor the changes in the pressure.

0.02 in. Leak Pressure Measurement
The purpose of this measurement is to confirm leak detection pump operation, and to provide a baseline measurement value that will be used for comparison in subsequent leak test steps.
The vent valve remains off, atmospheric pressure is introduced into the charcoal canister assembly and the ECM actuates the leak detection pump, creating a vacuum in the piping close to the canister pressure sensor.
At this time, the pressure will not decrease below what is referred to as the 0.02 in. pressure due to the atmospheric pressure that enters the piping close to the pump and sensor through the 0.02 in. diameter reference orifice.
The ECM compares its standard and this pressure. If the pressure is within the acceptable range, the ECM stores this pressure as the 0.02 in. leak pressure.
If the pressure is below the standard, the ECM will determine that the reference orifice is clogged and store DTC P043E in its memory.
If the pressure is above the standard, the ECM will determine that a high flow rate pressure is passing through the reference orifice and store DTCs P043F, P2401 and P2402 in its memory.

EVAP Leak Check
While actuating the leak detection pump, the ECM turns the vent valve on in order to introduce a vacuum into the charcoal canister assembly.
When the pressure in the system stabilizes, the ECM compares this pressure and the 0.02 in. pressure in order to determine if a leak is present.
If the detected pressure is below the 0.02 in. pressure, the ECM determines that there is no leak.
If the detected pressure is above the 0.02 in. pressure and near atmospheric pressure, the ECM determines that there is a gross leak (large hole) and stores DTC P0455 in its memory.
If the detected pressure is above the 0.02 in. pressure, the ECM determines that there is a small leak (minor leak) and stores DTC P0456 in its memory.

Purge VSV Monitor
After completing an EVAP leak check, the ECM turns the purge VSV on (open) with the leak detection pump actuated, and introduces the atmospheric pressure from the intake manifold to the charcoal canister assembly.
If the pressure change at this time is within the normal range (a pressure change occurs), the ECM determines the condition to be normal.
If the pressure change is out of the normal range (insufficient pressure change occurs), the ECM will stop the purge VSV monitor (purge monitor) and store DTC P0441 in its memory.

Repeat 0.02 in. Leak Pressure Measurement
While the ECM operates the leak detection pump, the purge VSV and vent valve are turned off and a repeat 0.02 in. leak pressure measurement is performed.
The ECM compares the measured pressure with the pressure during the EVAP leak check.
If the pressure during the EVAP leak check is less than the repeat 0.02 in. leak pressure measurement, the ECM determines that there is no leak.
If the pressure during the EVAP leak check is above the repeat 0.02 in. leak pressure measurement, the ECM determines that there is a small leak and stores DTC P0456 in its memory.

Air Pressure Sensor
The ECM detects operation of the air injection system based on signals from the air pressure sensor as follows:

Air Injection Control Driver
A semiconductor type air injection control driver is used. Activated by the ECM, this driver actuates the air pump assembly and the emission control valve set.
The air injection control driver also detects failures in the input and output circuits of the air injection driver and transmits the failure status to the ECM via duty cycle signals.

| Condition | AIRP | AIRV | Output (Duty Cycle Signal) |
| Open circuit in line between AIDI and DI terminals. | - | - | ![]() |
| Failure in line between ECM terminals and air injection control driver. | - | - | ![]() |
| Output failure at air injection control driver. (Failure in air pump assembly actuation circuit) | - | - | ![]() |
| Output failure at air injection control driver. (Failure in emission control valve actuation circuit) | - | - | ![]() |
| Overheat failure of air injection control driver. | - | - | ![]() |
| Normal | On | On | ![]() |
| Off | Off | ![]() | |
| On | Off | ||
| Off | On |