Home › Engine / Hybrid System › 1GR-FE ENGINE CONTROL › SFI SYSTEM

SFI SYSTEM > CHECK FOR INTERMITTENT PROBLEMS

for Preparation Click here


HINT:
Inspect the ECM using check mode. Intermittent problems are easier to detect with Techstream when the ECM is in check mode. In check mode, the ECM uses 1 trip detection logic, which is more sensitive to malfunctions than normal mode (default), which uses 2 trip detection logic.
  1. Clear the DTCs (Click here).
  2. Switch the ECM from normal mode to check mode using the Techstream (Click here).
  3. Perform a simulation test.
  4. Check and wiggle the harness(es), connector(s) and terminal(s).