Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR

ROOM TEMPERATURE SENSOR > INSPECTION

for Preparation Click here



1. INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)


E201245E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    HINT:
    As the temperature increases, the resistance decreases (refer to the graph).

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
    1. When measuring the resistance, make sure the sensor temperature is the same as the ambient temperature.

    If the result is not as specified, replace the cooler thermistor (room temperature sensor).
    Text in Illustration 
    *a
    Component without harness connected
    (Cooler Thermistor (Room Temperature Sensor))
    *b
    Resistance (kΩ)
    *c
    Temperature (°C(°F))