OCCUPANT CLASSIFICATION SYSTEM > INITIALIZATION |
| ZERO POINT CALIBRATION |
Zero point calibration and sensitivity check procedures
Adjust the seat position according to the table below.
| Adjustment Component | Position |
| Slide Direction | Rearmost position |
| Reclining Angle | Upright position |
| Headrest Height | Lowest position |
| Lifter Height | Lowest position |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Perform the zero point calibration by following the prompts on the screen.
Perform the sensitivity check by following the prompts on the screen.
Confirm that the beginning sensor reading is within the standard range.
Place a 30 kg (66.1 lb) weight (e.g. a 30 kg [66.1 lb] lead weight) onto the front passenger seat.
Confirm that the sensitivity is within the standard range.