Set the spiral cable to the center position .
After setting the spiral cable to the center position, rotate the spiral cable 2.5 times clockwise and measure the resistance according to the value(s) in the table below. Then rotate the spiral cable 5 times counterclockwise and measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
F24-1 - z12-2
| Always
| Below 1 Ω
|
F24-2 - z12-1
| Always
| Below 1 Ω
|
F24-3 - z13-2
| Always
| Below 1 Ω
|
F24-4 - z13-1
| Always
| Below 1 Ω
|
F23-6 - z11-10
| Always
| Below 1 Ω
|
F23-5 - z11-9
| Always
| Below 1 Ω
|
F23-4 - z11-8
| Always
| Below 1 Ω
|
F23-3 - z11-7
| Always
| Below 1 Ω
|
F23-2 - z11-6
| Always
| Below 1 Ω
|
F23-1 - z9-3
| Always
| Below 1 Ω
|
F23-12 - z11-5
| Always
| Below 1 Ω
|
F23-11 - z11-4
| Always
| Below 1 Ω
|
F23-10 - z11-3
| Always
| Below 1 Ω
|
F23-9 - z11-2
| Always
| Below 1 Ω
|
F23-8 - z11-1
| Always
| Below 1 Ω
|
F23-7 - z9-1
| Always
| Below 1 Ω
|
After setting the spiral cable to the center position, rotate the spiral cable 2.5 times clockwise. Then, while rotating the spiral cable 5 times counterclockwise, measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
F24-1 - z12-2
| Always
| Below 1 Ω
|
F24-2 - z12-1
| Always
| Below 1 Ω
|
F24-3 - z13-2
| Always
| Below 1 Ω
|
F24-4 - z13-1
| Always
| Below 1 Ω
|
F23-6 - z11-10
| Always
| Below 1 Ω
|
F23-5 - z11-9
| Always
| Below 1 Ω
|
F23-4 - z11-8
| Always
| Below 1 Ω
|
F23-3 - z11-7
| Always
| Below 1 Ω
|
F23-2 - z11-6
| Always
| Below 1 Ω
|
F23-1 - z9-3
| Always
| Below 1 Ω
|
F23-12 - z11-5
| Always
| Below 1 Ω
|
F23-11 - z11-4
| Always
| Below 1 Ω
|
F23-10 - z11-3
| Always
| Below 1 Ω
|
F23-9 - z11-2
| Always
| Below 1 Ω
|
F23-8 - z11-1
| Always
| Below 1 Ω
|
F23-7 - z9-1
| Always
| Below 1 Ω
|
- NOTICE:
- As the spiral cable may break, do not rotate the spiral cable more than the specified amount.