VALVE BODY ASSEMBLY > INSPECTION |
| 1. INSPECT SHIFT SOLENOID VALVE SR |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve SR connector terminal - Shift solenoid valve SR body | 20°C (68°F) | 11 to 15 Ω |
| *a | Component without harness connected (Shift Solenoid Valve SR) |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| 2. INSPECT SHIFT SOLENOID VALVE SLU AND SLT |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *a | Component without harness connected (Shift Solenoid Valve) |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| 3. INSPECT SHIFT SOLENOID VALVE SL1 AND SL2 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *a | Component without harness connected (Shift Solenoid Valve) |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| 4. INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body | 20°C (68°F) | 11 to 15 Ω |
| *a | Component without harness connected Shift Solenoid Valve S1 |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| 5. INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body | 20°C (68°F) | 11 to 15 Ω |
| *a | Component without harness connected Shift Solenoid Valve S2 |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |