AIR CONDITIONING PRESSURE SENSOR > INSTALLATION |
| 1. INSTALL NO. 1 PRESSURE SWITCH |
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the No. 1 pressure switch.
Install the O-ring to the No. 1 pressure switch.
Install the No. 1 pressure switch.
Connect the connector.
| 2. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 3. WARM UP ENGINE |
Warm up the engine at less than 1850 rpm for 2 minutes or more after charging the refrigerant.
| 4. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:
![]() |
Using a halogen leak detector, check the refrigerant line for leakage.
| *1 | Halogen Leak Detector |
| *a | Check for Leakage |
If a gas leak from the drain hose is not detected, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.
| 5. INSTALL RADIATOR GRILLE |
Install the radiator grille (Click here).
| 6. INSTALL UPPER RADIATOR SUPPORT SEAL |
Install the upper radiator support seal with the 13 clips.