- Connect the positive (+) battery terminal to terminal 2 (B), and connect the negative (-) battery terminal to terminal 1 (GND), and keep them connected for 3 seconds or more.
- With terminals 2 (B) and 1 (GND) connected to the battery, connect the negative (-) battery terminal to terminal 10 (UP).
- Disconnect and reconnect the negative (-) battery terminal to terminal 10 (UP) within 1 second.
| Motor gear rotates clockwise (Up)
|
- Connect the positive (+) battery terminal to terminal 2 (B), and connect the negative (-) battery terminal to terminal 1 (GND), and keep them connected for 3 seconds or more.
- With terminals 2 (B) and 1 (GND) connected to the battery, connect the negative (-) battery terminal to terminal 7 (DOWN).
- Disconnect and reconnect the negative (-) battery terminal to terminal 7 (DOWN) within 1 second.
| Motor gear rotates counterclockwise (Down)
|