HAZARD WARNING SWITCH > INSPECTION |
| 1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 4 (B1) - 1 (E) | Hazard warning signal switch off | 10 kΩ or higher |
| Hazard warning signal switch on | Below 1 Ω |
Apply battery voltage to the connector and check the LED illumination condition.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 3 (ILL+) Battery negative (-) → Terminal 2 (ILL-) | LED illuminates |
| *a | Component without harness connected (Hazard Warning Signal Switch Assembly) |