POWER SEAT SWITCH > INSPECTION |
| 1. INSPECT FRONT POWER SEAT SWITCH LH |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 5 (SLDF) - 8 (B) 5 (SLDF) - 7 (B2) | Front | Below 1 Ω |
| 2 (SLDR) - 11 (E) 2 (SLDR) - 12 (E1) | ||
| 5 (SLDF) - 11 (E) 5 (SLDF) - 12 (E1) | Off | |
| 2 (SLDR) - 11 (E) 2 (SLDR) - 12 (E1) | ||
| 5 (SLDF) - 11 (E) 5 (SLDF) - 12 (E1) | Rear | |
| 2 (SLDR) - 8 (B) 2 (SLDR) - 7 (B2) |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (FUP) - 8 (B) 1 (FUP) - 7 (B2) | Up | Below 1 Ω |
| 6 (FDWN) - 11 (E) 6 (FDWN) - 12 (E1) | ||
| 1 (FUP) - 11 (E) 1 (FUP) - 12 (E1) | Off | |
| 6 (FDWN) - 11 (E) 6 (FDWN) - 12 (E1) | ||
| 1 (FUP) - 11 (E) 1 (FUP) - 12 (E1) | Down | |
| 6 (FDWN) - 8 (B) 6 (FDWN) - 7 (B2) |
| Tester Connection | Switch Condition | Specified Condition |
| 3 (LUP) - 8 (B) 3 (LUP) - 7 (B2) | Up | Below 1 Ω |
| 4 (LDWN) - 11 (E) 4 (LDWN) - 12 (E1) | ||
| 3 (LUP) - 11 (E) 3 (LUP) - 12 (E1) | Off | |
| 4 (LDWN) - 11 (E) 4 (LDWN) - 12 (E1) | ||
| 3 (LUP) - 11 (E) 3 (LUP) - 12 (E1) | Down | |
| 4 (LDWN) - 8 (B) 4 (LDWN) - 7 (B2) |
| Tester Connection | Switch Condition | Specified Condition |
| 10 (RCLF) - 8 (B) 10 (RCLF) - 7 (B2) | Front | Below 1 Ω |
| 9 (RCLR) - 11 (E) 9 (RCLR) - 12 (E1) | ||
| 10 (RCLF) - 11 (E) 10 (RCLF) - 12 (E1) | Off | |
| 9 (RCLR) - 11 (E) 9 (RCLR) - 12 (E1) | ||
| 10 (RCLF) - 11 (E) 10 (RCLF) - 12 (E1) | Rear | |
| 9 (RCLR) - 8 (B) 9 (RCFR) - 7 (B2) |
| *1 | Front Vertical Switch |
| *2 | Slide Switch |
| *3 | Lifter Switch |
| *4 | Reclining Switch |
| *a | Component without harness connected (Front Power Seat Switch) |
| 2. INSPECT FRONT POWER SEAT SWITCH RH |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 2 (SLDF) - 13 (B) | Front | Below 1 Ω |
| 5 (SLDR) - 10 (E) | ||
| 2 (SLDF) - 10 (E) | Off | |
| 5 (SLDR) - 10 (E) | ||
| 2 (SLDF) - 10 (E) | Rear | |
| 5 (SLDR) - 13 (B) |
| Tester Connection | Switch Condition | Specified Condition |
| 11 (RCLF) - 13 (B) | Front | Below 1 Ω |
| 12 (RCLR) - 10 (E) | ||
| 11 (RCLF) - 10 (E) | Off | |
| 12 (RCLR) - 10 (E) | ||
| 11 (RCLF) - 10 (E) | Rear | |
| 12 (RCLR) - 13 (B) |
| *1 | Slide Switch |
| *2 | Reclining Switch |
| *a | Component without harness connected (Front Power Seat Switch) |