Home
›
Engine / Hybrid System
›
FA20 ENGINE CONTROL
›
KNOCK SENSOR
KNOCK SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT KNOCK SENSOR
Measure the resistance according to the value(s) the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
532 to 588 kΩ
Text in Illustration
*a
Component without harness connected
(Knock Sensor)
If the result is not as specified, replace the knock sensor.