Home › Drivetrain ยท TX6A AUTOMATIC TRANSMISSION / TRANSAXLE › OIL PUMP

OIL PUMP > INSPECTION

for Preparation Click here



1. INSPECT STATOR SHAFT ASSEMBLY


    C257589
  1. Using a caliper gauge, measure the inside diameter of the stator shaft bushing.

    Standard inside diameter:
    21.527 mm (0.8475 in.)

    If the inside diameter is more than the standard inside diameter, replace the stator shaft assembly.



2. INSPECT OIL PUMP DRIVE GEAR ROTATION


    C108581
  1. Make sure that the drive gear rotates smoothly.

  1. Remove the oil pump assembly from the torque converter assembly.