Standard Voltage
Terminal No. (Symbol)
| Wiring Color
| Terminal Description
| Condition
| Specified Condition
|
A16-3 (HDLP) - Body ground
| L - Body ground
| Low beam headlight signal input
| Low beam headlights on
| Below 1.5 V
|
Low beam headlights off
| 5 V or higher
|
A16-5 (INIT) - Body ground
| BR - Body ground
| Initialization signal input
| Terminals LVL and GND of DLC3 connected
| Below 1 V
|
Terminals LVL and GND of DLC3 not connected
| 4.5 to 5.5 V
|
A16-6 (WNG) - Body ground
| Y - Body ground
| Warning indicator drive output
| Warning indicator on
| Below 1 V
|
Warning indicator off
| 11 to 14 V
|
A16-10 (RH1) - Body ground
| W-R - Body ground
| Leveling motor RH power supply
| Ignition switch off
| Below 1 V
|
Ignition switch ON
| 11 to 14 V
|
A16-11 (LH1) - Body ground
| R-W - Body ground
| Leveling motor LH power supply
| Ignition switch off
| Below 1 V
|
Ignition switch ON
| 11 to 14 V
|
A16-12 (SBR) - Body ground
| G-W - Body ground
| Rear height control sensor power supply
| Ignition switch off
| Below 1 V
|
Ignition switch ON
| 4.75 to 5.25 V
|
A16-16 (SPDR) - Body ground
| P-G - Body ground
| Vehicle speed signal input
| Vehicle driven at approx. 20 km/h (12mph)
| Pulse generation (See waveform 1)
|
A16-17 (RH2) - Body ground
| R - Body ground
| Leveling motor RH operation signal input
| With low beam headlights on, vehicle height not changed
| Below 1 V
|
With low beam headlights on, vehicle height changed and maintained for more than 3 seconds
| 1.0 to 14.4 V
|
A16-18 (LH2) - Body ground
| L - Body ground
| Leveling motor LH operation signal input
| With low beam headlights on, vehicle height not changed
| Below 1 V
|
With low beam headlights on, vehicle height changed and maintained for more than 3 seconds
| 1.0 to 14.4 V
|
A16-19 (SHR) - Body ground
| G - Body ground
| Rear height control sensor signal input
| Ignition switch off
| Below 1 V
|
Ignition switch ON
| 0.5 to 4.5 V
|