DTC B1432/22 Open in Ambient Temperature Sensor Circuit |
DTC B1433/-22 Short in Ambient Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1432/22 | Open in ambient temperature sensor circuit |
|
| B1433/-22 | Short in ambient temperature Sensor circuit |
|

| 1.READ VALUE USING GTS |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Ambient Temp Sensor (Ambi Temp Sens) | Ambient temperature sensor (thermistor assembly) / Min: -40.00°C (-40.00°F) Max: 80.00°C (176.00°F) | Actual ambient temperature displayed | - |
| Result | Proceed to |
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK FOR DTC |
Clear the DTCs
Check the DTCs
|
| ||||
| OK | ||
| ||
| 3.INSPECT AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY) |
Remove the ambient temperature sensor (thermistor assembly) .
Inspect the ambient temperature sensor (thermistor assembly) .
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY) - COMBINATION METER ASSEMBLY) |
Disconnect the D7 conditioning meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A48-1 - D7-24(TAM) | Always | Below 1 Ω |
| A48-2 - D7-25(SG-) | Always | Below 1 Ω |
| A48-1 - Body ground | Always | 10 kΩ or higher |
| A48-2 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||