Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1434/23    Open in Evaporator Sensor Circuit

DTC    B1435/-23    Short in Evaporator Sensor Circuit

for Preparation Click here


DESCRIPTION

The evaporator temperature sensor (No. 1 cooler thermistor) is installed on the No. 1 cooler evaporator sub-assembly in the air conditioner unit to detect the temperature of the air that has passed through the No. 1 cooler evaporator sub-assembly and is used to control the air conditioning. It sends signals to the air conditioning control assembly. The resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes in accordance with the cooled air temperature that has passed through the No. 1 cooler evaporator sub-assembly. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning control assembly applies voltage (5 V) to the evaporator temperature sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.

DTC No.
DTC Detection Condition
Trouble Area
B1434/23
Open in evaporator sensor circuit
  1. Evaporator temperature sensor (No. 1 cooler thermistor)
  2. Harness or connector between evaporator temperature sensor (No. 1 cooler thermistor) and air conditioning control assembly
  3. Air conditioning control assembly
B1435/-23
Short in evaporator sensor circuit
  1. Evaporator temperature sensor (No. 1 cooler thermistor)
  2. Harness or connector between evaporator temperature sensor (No. 1 cooler thermistor) and air conditioning control assembly
  3. Air conditioning control assembly

WIRING DIAGRAM


E248912E01


INSPECTION PROCEDURE

1.READ VALUE USING GTS
  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Enter the following menus: Body Electrical / Air Conditioner / Data List.

  1. Check the value(s) by referring to the table below.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Evaporator Temp Sensor
    (Evap Temp)
    Evaporator temperature sensor (No. 1 cooler thermistor) /
    Min.: -82.48°C (-116.46°F)
    Max.: 153.55°C (308.39°F)
    Actual evaporator temperature displayed
    -

    OK:
    The display is as specified in the normal condition column.

    Result:
    Result
    Proceed to
    OK (When troubleshooting according to the DTC)
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    NG
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
Go to step 3
A


Go to step 3

2.CHECK FOR DTC
  1. Clear the DTCs (Click here)

  1. Check the DTCs (Click here)

    OK:
    DTC is not output.



NG
REPLACE AIR CONDITIONING CONTROL ASSEMBLY
OK

END 

3.INSPECT EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR)
  1. Remove the evaporator temperature sensor (No. 1 cooler thermistor) .

  1. Inspect the evaporator temperature sensor (No. 1 cooler thermistor)



NG
REPLACE EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR)
OK


4.CHECK HARNESS AND CONNECTOR (EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR) - AIR CONDITIONING CONTROL ASSEMBLY)
  1. Disconnect the D20 air conditioning control assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A25-1 - D20-17(TE)
    Always
    Below 1 Ω
    A25-2 - D20-6(SG)
    Always
    Below 1 Ω
    A25-1 - Body ground
    Always
    10 kΩ or higher
    A25-2 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING CONTROL ASSEMBLY