DTC B1434/23 Open in Evaporator Sensor Circuit |
DTC B1435/-23 Short in Evaporator Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1434/23 | Open in evaporator sensor circuit |
|
| B1435/-23 | Short in evaporator sensor circuit |
|

| 1.READ VALUE USING GTS |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Evaporator Temp Sensor (Evap Temp) | Evaporator temperature sensor (No. 1 cooler thermistor) / Min.: -82.48°C (-116.46°F) Max.: 153.55°C (308.39°F) | Actual evaporator temperature displayed | - |
| Result | Proceed to |
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| Go to step 3 |
| 2.CHECK FOR DTC |
Clear the DTCs (Click here)
Check the DTCs (Click here)
|
| ||||
| OK | ||
| ||
| 3.INSPECT EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR) |
Remove the evaporator temperature sensor (No. 1 cooler thermistor) .
Inspect the evaporator temperature sensor (No. 1 cooler thermistor)
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR) - AIR CONDITIONING CONTROL ASSEMBLY) |
Disconnect the D20 air conditioning control assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A25-1 - D20-17(TE) | Always | Below 1 Ω |
| A25-2 - D20-6(SG) | Always | Below 1 Ω |
| A25-1 - Body ground | Always | 10 kΩ or higher |
| A25-2 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||