DRIVE BELT > REMOVAL |
| 1. REMOVE AIR CLEANER CAP WITH AIR CLEANER HOSE |
![]() |
Loosen the hose clamp and disconnect the No. 2 ventilation hose.
![]() |
Disconnect the mass air flow meter connector.
Disengage the clamp and separate the wire harness from the air cleaner cap.
![]() |
Loosen the 2 hose clamps.
![]() |
Remove the 3 bolts and the air cleaner cap with air cleaner hose.
| 2. REMOVE GENERATOR COVER |
![]() |
Remove the 2 bolts and generator cover.
| 3. REMOVE BELT GENERATOR COVER |
![]() |
Disengage the 2 clamps and separate the wire harness from the belt generator cover.
Remove the 2 bolts and belt generator cover.
| 4. REMOVE FAN AND GENERATOR V BELT |
![]() |
While turning the belt tensioner clockwise, align the holes and insert a 3 mm (0.118 in.) hexagon wrench into the holes to hold the belt tensioner.
| *1 | Hexagon Wrench |
Remove the fan and generator V belt from the belt tensioner.