INJECTOR DRIVER > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE INJECTOR DRIVER |
![]() |
Move the lock levers in the direction indicated by the arrow to release the 3 connector locks. Disconnect the 4 connectors from the injector driver.
| *1 | Lock Lever |
| *a | Release |
![]() | Lock with Connector |
![]() | Normal Connector |
![]() |
Remove the 3 bolts and injector driver.