OUTER MIRROR SWITCH > INSPECTION |
| 1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for RHD) |
![]() |
Check the switch functions.
Turn the mirror select switch to the L position.
Measure the resistance according to the value(s) in the table below.
| *1 | Mirror Select Switch |
| *2 | Mirror Surface Adjust Switch |
| *3 | Mirror Retract Switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 14 (ML+) 10 (VL) - 7 (E) | UP | Below 1 Ω |
| 1 (B) - 10 (VL) 14 (ML+) - 7 (E) | DOWN | Below 1 Ω |
| 1 (B) - 8 (HL) 14 (ML+) - 7 (E) | LEFT | Below 1 Ω |
| 1 (B) - 14 (ML+) 8 (HL) - 7 (E) | RIGHT | Below 1 Ω |
Turn the mirror select switch to the R position.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 12 (MR+) 11 (VR)- 7 (E) | UP | Below 1 Ω |
| 1 (B) - 11 (VR) 12 (MR+) - 7 (E) | DOWN | Below 1 Ω |
| 1 (B) - 9 (HR) 12 (MR+) - 7 (E) | LEFT | Below 1 Ω |
| 1 (B) - 12 (MR+) 9 (HR) - 7 (E) | RIGHT | Below 1 Ω |
Check the mirror retract switch. (w/ Mirror Retract Switch)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 6 (MFR) 3 (MRR) - 7 (E) | Mirror retract switch retract position | Below 1 Ω |
| 1 (B) - 3 (MRR) 6 (MFR) - 7 (E) | Mirror retract switch return position |
| 2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for LHD) |
![]() |
Check the switch functions.
Turn the mirror select switch to the L position.
Measure the resistance according to the value(s) in the table below.
| *1 | Mirror Select Switch |
| *2 | Mirror Surface Adjust Switch |
| *3 | Mirror Retract Switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 14 (ML+) 10 (VL) - 7 (E) | UP | Below 1 Ω |
| 1 (B) - 10 (VL) 14 (ML+) - 7 (E) | DOWN | Below 1 Ω |
| 1 (B) - 8 (HL) 14 (ML+) - 7 (E) | LEFT | Below 1 Ω |
| 1 (B) - 14 (ML+) 8 (HL) - 7 (E) | RIGHT | Below 1 Ω |
Turn the mirror select switch to the R position.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 12 (MR+) 11 (VR)- 7 (E) | UP | Below 1 Ω |
| 1 (B) - 11 (VR) 12 (MR+) - 7 (E) | DOWN | Below 1 Ω |
| 1 (B) - 9 (HR) 12 (MR+) - 7 (E) | LEFT | Below 1 Ω |
| 1 (B) - 12 (MR+) 9 (HR) - 7 (E) | RIGHT | Below 1 Ω |
Check the mirror retract switch. (w/ Mirror Retract Switch)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 6 (MFR) 3 (MRR) - 7 (E) | Mirror retract switch retract position | Below 1 Ω |
| 1 (B) - 3 (MRR) 6 (MFR) - 7 (E) | Mirror retract switch return position |