AUTOMATIC LIGHT CONTROL SENSOR > INSPECTION |
| 1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR |
![]() |
Disconnect the D45 automatic light control sensor connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D45-3 (CLTB) - D45-6 (CLTE) | Ignition switch OFF | Below 1 V |
| Ignition switch ON | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
| D45-6 (CLTE) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector (to Automatic Light Control Sensor) |
![]() |
Reconnect the D45 automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.
| Tester Connection | Tool Setting | Switch Condition | Specified Condition |
| D45-4 (CLTS) - D45-6 (CLTE) | 5 V/DIV., 5 ms./DIV | Ignition switch ON, light control switch in AUTO position | Correct waveform is as shown |
| *a | Component with harness connected (Automatic Light Control Sensor) |