AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor (Room Temp) | Room temperature sensor / Min.: -72.47°C (-98.4°F) Max.: 193.82°C (380.9°F) | Actual cabin temperature displayed | - |
| Solar Sensor (Solar Sens) | Solar sensor / Min.: 0W/m2 Max.: 4448W/m2 | Solar sensor value increases as brightness increases | - |
| Pressure Switch Operation (Pressure Switch Oper) | Pressure Switch / Normal.: 0 Abnormal.: 225 | - | - |
| Engine Coolant Temp (Coolant Temp) | Engine coolant temperature sensor / Min.: -40.00°C (-40.00°F) Max.: 215.00°C (419°F) | Actual engine coolant temperature is displayed | - |
| Set Temperature (D Side) (Set Temp-D) | Driver side set temperature / Min.: 18.00°C (64.40°F) Max.: 32.00°C (89.60°F) | Driver side set temperature displayed | - |
| Set Temperature (P Side) (Set Temp-P) | Passenger side set temperature / Min.: 18°C (65°F) Max.: 32°C (85°F) | Passenger side set temperature displayed | - |
| Air Outlet Servo Temp (D Side) (Air Out Serv Temp-D) | Driver side air outlet temperature / Min.: -327.68°C (-557.8°F) Max.: 327.67°C (621.8°F) | Driver side air outlet temperature displayed | - |
| Air Outlet Servo Temp (P Side) (Air Out Serv Temp-P) | Passenger side air outlet temperature / Min.: -327.68°C (-557.8°F) Max.: 327.67°C (621.8°F) | Passenger side air outlet temperature displayed | - |
| Air Mix Damper Position (D) (A/M Damp Pos-D) | Driver side air mix damper position / Min.: -32.68% Max.: -133.33% | MAX. COLD: 0% MAX. HOT: 110% | - |
| Air Mix Damper Position (P) (A/M Damp Pos-P) | Passenger side air mix damper position / Min.: -32.68% Max.: -133.33% | MAX. COLD: 0% MAX. HOT: 110% | - |
| Air Outlet Damper Position (A/O Damp Pos) | Air outlet damper position / Min.: -32.68% Max.: -133.33% | FACE: -16.7% B/L: 10% FOOT-0: 50% (Manual operation) FOOT: 70% FOOT/DEF: 90% DEF: 116.7% | - |
| Air Inlet Damper Position (A/I Damp Pos) | Air inlet damper position / Min.: 0 Max.: 100 | Inside: 0 Outside: 100 | - |
| Air Mix Damper Target (D) (A/M Damp Targ-D) | Driver side air mix damper target position / Min.: -32.68% Max.: 133.33% | MAX. COLD: 0% MAX. HOT: 110% | - |
| Air Mix Damper Target (P) (A/M Damp Targ-P) | Passenger side air mix damper target position / Min.: -32.68% Max.: 133.33% | MAX. COLD: 0% MAX. HOT: 110% | - |
| Air Outlet Damper Target (A/O Damp Targ) | Air outlet damper target position / Min.: -32.68% Max.: 133.33% | FACE: -16.7% B/L: 10% FOOT-0: 50% (Manual operation) FOOT: 70% FOOT/DEF: 90% DEF: 116.7% | - |
| Air Inlet Damper Target (A/I Damp Targ) | Air outlet damper target position / REC or FRC | Inside: REC Outside: FRC | - |
| Blower Motor Speed Level (Blower Level) | Blower motor speed level / Min.: 0 Max.: 31 | Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Ambient Temp Sensor (Ambi Temp Sens) | Ambient temperature sensor (thermistor assembly) / Min.: -40.00°C (-40.00°F) Max.: 80.00°C (176.00°F) | Actual ambient temperature displayed | - |
| Status of Compressor Operation (Stat of Compre Oper) | Status of compressor operation ON or OFF | Compressor operation ON: ON Compressor operation OFF: OFF | - |
| Status of Blower Fan Operation (Status Blow Fan Oper) | Status of blower fan operation Manual or Auto | Blower fan manual operation: Manual Blower fan auto operation: Auto | - |
| Status of Air Conditioner Operation (Status Air Cond Oper) | Status of air conditioner operation Manual or Auto | Air conditioner manual operation: Manual Air conditioner Auto operation: Auto | - |
| Status of Air Inlet Damper Operation (Sta Air Inl Damp Ope) | Status of air inlet damper operation Manual or Auto | Air inlet damper manual operation: Manual Air inlet damper Auto operation: Auto | - |
| Status of Air Outlet Damper Operation (Sta Air Out Damp Ope) | Status of air outlet damper operation Manual or Auto | Air outlet damper manual operation: Manual Air outlet damper Auto operation: Auto | - |
| Defogger Relay (Rear) (Defogger Relay Rr) | Rear window defogger operation ON or OFF | Rear window defogger operation ON: ON Rear window defogger operation OFF: OFF | - |
| Engine Spd (Engin Spd) | Engine speed Min.: 0 rpm Max.: 32767 rpm | - | - |
| Vehicle Spd (Vehic Spd) | Vehicle speed Min.: 0.00 km/h Max.: 300.00 km/h | - | - |
| Evaporator Temp Sensor (Evap Temp) | Evaporator temperature sensor (No. 1 cooler thermistor) / Min.: -82.48°C (-116.46°F) Max.: 153.55°C (308.39°F) | Actual evaporator temperature displayed | - |
| Evaporator Target Temp (Evap Tag Temp) | Evaporator temperature sensor (No. 1 cooler thermistor) / Min.: 0.00°C (32.0°F) Max.: 20.00°C (68.0°F) | - | - |
| Air Inlet Mode (Air Inlet Mode) | Air inlet mode / Auto or Manual | Customized value displayed | - |
| Compressor Mode (Compressor Mode) | Compressor mode / Auto or Manual | Customized value displayed | - |
| Compressor/Air Inlet DEF Operation (Comprs/DEF Oper) | Compressor/air inlet DEF operation / Link or Normal | Customized value displayed | - |
| DEF (PSW/Lock) Mode Setting (DEF (PSW/Lock) Md Set) | DEF (PSW/Lock) mode setting Link or Normal | Customized value displayed | - |
| Foot/DEF Automatic Blow Up Function (Auto Blow Up) | Foot/DEF Automatic Blow Up Function ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Mode (Foot/DEF Mode) | Foot/DEF auto mode / Auto or Manual | Customized value displayed | - |
| Set Temperature Shift (Set Temp Shift) | Set temperature shift Min.: -3°C Max.: +3°C | Customized value displayed | - |
| Number of Trouble Codes (#Codes) | Number of trouble codes / Min.: 0 Max.: 255 | Number of DTCs displayed | - |
| ACTIVE TEST |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Air Mix Damper (D) | No. 5 air conditioning radiator damper servo sub-assembly (air mix*1) | Min.: 0.00, Max.: 110.00
| - |
| Air Mix Damper (P) | No. 4 air conditioning radiator damper servo sub-assembly (air mix*2) | Min.: 0.00, Max.: 110.00
| - |
| Air Outlet Damper | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) | Min.: -16.7, Max.: 116.7 | - |
| Solar Sensor | Solar Sensor | Min.: 0, Max.: 4448 | - |
| Auto Switch | Auto Switch | OFF, ON | - |
| Defogger Relay (Rear) | Defogger relay (engine room relay block assembly) | OFF, ON | - |
| Magnetic Clutch Relay | A/C system operation | OFF, ON | - |
| Inside and Outside Change | Blower damper servo sub-assembly (air inlet) | Inside, Outside | - |