REFRIGERANT (for HFC-134a(R134a)) > REPLACEMENT |
| 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
Start the engine.
Operate the cooler compressor under the conditions shown below:
| Item | Condition |
| Engine Speed | Idling |
| Operating Time | 3 minutes or more |
| A/C Switch Status | On |
| Blower Switch Status | HI |
| Set Temperature | MAX COOL |
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
| 2. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| *a | Amount to be charged | *b | Charge 100 g (3.53 oz) |
| *c | Mean value in proper range | *d | Point where bubbles disappear |
| *e | Overcharged | *f | Pressure |
| *g | Sub-cool system | *h | Refrigerant amount |
| 3. WARM UP ENGINE |
Warm up the engine at less than 2000 rpm for 2 minutes or more after charging the refrigerant.
| 4. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation observing the following instructions:
![]() |
Using a halogen leak detector, check the refrigerant line for leakage.
If a gas leak is not detected from the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and check for gas leakage.
Disconnect the pressure switch connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and check for gas leakage.
| *1 | Halogen Leak Detector |
| *a | Check for Leakage |