METER / GAUGE SYSTEM > Entire Combination Meter does not Operate |

| 1.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND) |
![]() |
Disconnect the D7 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D7-1 (B) - Body ground | Always | 11 to 14 V |
| D7-2 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
Measure the resistance according to the value in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-20 (ES1) - Body ground | Always | Below 1 Ω |
| D7-40 (ES2) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector (to Combination Meter Assembly) |
Reconnect the D7 combination meter assembly connector.
|
| ||||
| OK | ||
| ||