TURN SIGNAL FLASHER ASSEMBLY > INSPECTION |
| 1. INSPECT TURN SIGNAL FLASHER ASSEMBLY |
![]() |
Disconnect the D61 turn signal flasher assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D61-4 (+B) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |
| D61-1 (IG) - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector (to Turn Signal Flasher Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D61-7 (GND) - Body ground | Always | Below 1 Ω |
![]() |
Reconnect the D61 turn signal flasher assembly connector.
Measure the voltage according to the valve(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D61-6 (ER) - Body ground | Turn signal switch in RH position OFF to ON | 9 V or higher to below 1 V |
| D61-5 (EL) - Body ground | Turn signal switch in LH position OFF to ON | 9 V or higher to below 1 V |
| D61-8 (EHW) - Body ground | Hazard warning switch OFF to ON | 9 V or higher to below 1 V |
| D61-2 (LR) - Body ground | Turn signal switch in RH position OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| D61-3 (LL) - Body ground | Turn signal switch in LH position OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| D61-2 (LR) - Body ground | Hazard warning switch OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| D61-3 (LL) - Body ground | Hazard warning switch OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| *a | Component with harness connected (Turn Signal Flasher Assembly) |