Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR

ROOM TEMPERATURE SENSOR > INSPECTION

for Preparation Click here



1. INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR


    E161677E41
  1. Disconnect the connector from the cooler (room temp. sensor) thermistor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Hold the sensor only by its connector. Touching the sensor may change the resistance value.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    If the resistance is not as specified, replace the cooler (room temp. sensor) thermistor.
    Text in Illustration 
    *a
    Component without harness connected
    (cooler (room temp. sensor) thermistor)
    *b
    Sensing Portion
    *c
    Resistance (kΩ)
    *d
    Allowable Range
    *e
    Temperature (°C (°F))