Home › General › SPECIFICATIONS › FA20 STARTING

FA20 STARTING > SERVICE DATA



Starter assembly
Standard current
Below 90 A at 11.5 V
Starter armature assembly
Standard runout
for Manual Transmission
0.05 mm (0.002 in.)
for Automatic Transmission
0.02 mm (0.0008 in.)
Maximum runout
for Manual Transmission
0.10 mm (0.004 in.)
for Automatic Transmission
0.05 mm (0.002 in.)
Standard depth
Segment - Mold
for Manual Transmission
0.50 mm (0.020 in.)
for Automatic Transmission
0.7 mm (0.0276 in.)
Minimum depth
Segment - Mold
for Automatic Transmission
0.20 mm (0.0079 in.)
Standard resistance
Segment - Segment
for Automatic Transmission
Below 1 Ω
Commutator - Armature coil core
for Automatic Transmission
10 kΩ or higher
Standard diameter
for Automatic Transmission
29 mm (1.1417 in.)
Minimum diameter
for Automatic Transmission
28 mm (1.1024 in.)
Brush length
Standard length
for Manual Transmission
12.3 mm (0.484 in.)
for Automatic Transmission
14.4 mm (0.5669 in.)
Minimum length
for Manual Transmission
7.0 mm (0.276 in.)
for Automatic Transmission
9.0 mm (0.3543 in.)
Standard brush spring force
for Manual Transmission
15.9 to 19.5 N (1.6 to 2.0 kgf, 3.6 to 4.4 lbf)
Minimum brush spring force
for Manual Transmission
2.5 N (0.3 kgf, 0.6 lbf)
Standard resistance
for Automatic Transmission
A - B
A - C
B - D
C - D
10 kΩ or higher
A - D
B - C
Below 1 Ω
Starter magnetic switch assembly
Standard resistance
Terminal 50 - Terminal C
for Manual Transmission
Below 1 Ω
for Automatic Transmission
Below 1 Ω
Standard resistance
Terminal 50 - Switch body
for Manual Transmission
Below 1 Ω
for Automatic Transmission
Below 2 Ω
Standard resistance
Terminal 30 - Terminal C
for Manual Transmission
1 MΩ or higher
Engine switch
1 (SSW2) - 6 (AGND)
Pushed
Below 1 Ω
Not pushed
10 kΩ or higher
5 (SSW1) - 6 (AGND)
Pushed
Below 1 Ω
Not pushed
10 kΩ or higher
Ignition switch assembly
Standard resistance
All combinations of all terminals
LOCK
10 kΩ or higher
Standard resistance
2 (AM1) - 3 (ACC)
ACC
Below 1 Ω
Standard resistance
2 (AM1) - 3 (ACC) - 4 (IG1)
6 (IG2) - 7 (AM2)
ON
Below 1 Ω
Standard resistance
1 (ST1) - 2 (AM1) -- 4 (IG1)
6 (IG2) - 7 (AM2) - 8 (ST2)
START
Below 1 Ω
Starter relay
Specified condition
1 - 2
(Battery voltage not applied to terminals 1 and 2)
(Measured temperature : 20 °C (68 °F))
93.8 to 136.4 kΩ
3 - 5
(Battery voltage is applied between terminals 1 and 2)
Below 1 Ω
3 - 5
(Battery voltage is not applied between terminals 1 and 2)
10 kΩ or higher
Inhibitor relay
Specified condition
1 - 2
(Battery voltage not applied to terminals 1 and 2)
(Measured temperature : 20 °C (68 °F))
93.8 to 136.4 kΩ
3 - 5
(Battery voltage is applied between terminals 1 and 2)
Below 1 Ω
3 - 5
(Battery voltage is not applied between terminals 1 and 2)
10 kΩ or higher
Starter cut relay
Specified condition
1 - 2
(Battery voltage not applied to terminals 1 and 2)
(Measured temperature : 20 °C (68 °F))
93.8 to 136.4 kΩ
3 - 4
(Battery voltage is applied between terminals 1 and 2)
10 kΩ or higher
3 - 4
(Battery voltage is not applied between terminals 1 and 2)
Below 1 Ω
3 - 5
(Battery voltage is applied between terminals 1 and 2)
Below 1 Ω
3 - 5
(Battery voltage is not applied between terminals 1 and 2)
10 kΩ or higher
Ignition S relay
Specified condition
1 - 2
(Battery voltage not applied to terminals 1 and 2)
(Measured temperature : 20 °C (68 °F))
93.8 to 136.4 kΩ
3 - 5
(Battery voltage is applied between terminals 1 and 2)
Below 1 Ω
3 - 5
(Battery voltage is not applied between terminals 1 and 2)
10 kΩ or higher