ROOM TEMPERATURE SENSOR > INSTALLATION |
| 1. INSTALL COOLER (ROOM TEMP. SENSOR) THERMISTOR (for RHD) |
Engage the 2 claws and install the cooler (room temp. sensor) thermistor.
| 2. INSTALL COOLER (ROOM TEMP. SENSOR) THERMISTOR (for LHD) |
| 3. INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (for RHD) |
for LHD
Engage the 3 claws and 4 clips and install the No. 2 instrument panel under cover sub-assembly.
for RHD
Engage the 3 claws and 4 clips.
Connect the cooler thermistor hose and connector and install the No. 2 instrument panel under cover sub-assembly.
| 4. INSTALL LOWER INSTRUMENT PANEL (for LHD) |
| 5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |