COMPRESSOR > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL LEVEL |
for HFC-134a (R134a):
![]() |
When replacing the compressor with motor assembly with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new compressor with motor assembly before installation.
for HFO-1234yf (R1234yf):
![]() |
When replacing the compressor with motor assembly with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new compressor with motor assembly before installation.
| 2. INSTALL COMPRESSOR WITH MAGNET CLUTCH |
![]() |
Install the compressor with magnet clutch with the 3 bolts.
Connect the connector.
| 3. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the compressor with magnet clutch.
Install the O-ring onto the No. 1 cooler refrigerant discharge hose.
Install the No. 1 cooler refrigerant discharge hose onto the compressor with magnet clutch with the bolt.
| 4. CONNECT SUCTION HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the compressor with magnet clutch.
Install the O-ring onto the suction hose sub-assembly.
Install the suction hose sub-assembly onto the compressor with magnet clutch with the bolt.
| 5. INSTALL FAN AND GENERATOR V BELT |
![]() |
Set the fan and generator V belt onto every part.
| *1 | Idler |
| *2 | Generator |
| *3 | Tensioner |
| *4 | Water Pump |
| *5 | Crankshaft |
| *6 | A/C Compressor (w/ Air Conditioning System) |
| Idler Pulley Bracket (w/o Air Conditioning System) |
While turning the belt tensioner clockwise, remove the 3 mm (0.118 in.) hexagon wrench.
Check that the fan and generator V belt fits properly in the ribbed grooves.
| 6. INSTALL BELT GENERATOR COVER |
Install the belt generator cover with the 2 blots.
Engage the 2 wire harness clamps and install the wire harness to the belt generator cover.
| 7. INSTALL GENERATOR COVER |
Install the generator cover with the 2 blots.
| 8. INSTALL AIR CLEANER ASSEMBLY |
Install the air cleaner cap with air cleaner hose with the 3 blots.
Install the air cleaner cap with air cleaner hose with the 2 hose clamps.
Connect the No. 2 ventilation hose.
Connect the mass air flow meter connector.
Engage the wire harness clamp and install the wire harness to the air cleaner cap.
| 9. CHARGE WITH REFRIGERANT |
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
| 10. WARM UP ENGINE |
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
| 11. INSPECT FOR REFRIGERANT LEAK |
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):