Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PANEL (for Manual Air Conditioning System)

AIR CONDITIONING PANEL (for Manual Air Conditioning System) > INSPECTION

for Preparation Click here



1. INSPECT NO. 3 HEATER CONTROL SUB-ASSEMBLY


    E246511E02
  1. Check the heater control assembly resistance.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    2(B) - 3(A/C)
    A/C switch OFF
    10 kΩ or higher
    2(B) - 4(AND)
    A/C switch OFF
    10 kΩ or higher
    3(A/C) - 4(AND)
    Always
    Below 1 Ω
    2(B) - 3(A/C)
    A/C switch ON
    Below 1 Ω
    2(B) - 4(AND)
    A/C switch ON
    Below 1 Ω
    5 - 6
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    A/C Switch
    *a
    Component without harness connected
    (No. 3 heater control sub-assembly)

  1. Check that the A/C Switch illumination.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → 5
    Battery negative (-) → 6
    illuminates

  1. Check that the indicator light.

    Standard:
    Tester Connection
    Switch Condition
    Specified Condition
    Battery positive (+) → 2
    Battery negative (-) → 4
    A/C switch OFF
    go out
    Battery positive (+) → 2
    Battery negative (-) → 4
    A/C switch ON
    come on



2. INSPECT HEATER CONTROL SUB-ASSEMBLY


    E250315E02
  1. Check the heater control assembly resistance.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    each terminal - 5
    A/C switch OFF
    10 kΩ or higher
    10 - 5
    A/C switch LO
    Below 1 Ω
    10 - 5 - 3
    A/C switch LO - M1
    Below 1 Ω
    10 - 5 - 3
    A/C switch M1
    Below 1 Ω
    10 - 5 - 3 - 6
    A/C switch M1 - M2
    Below 1 Ω
    10 - 5 - 6
    A/C switch M2
    Below 1 Ω
    10 - 5 - 6 - 1
    A/C switch M2 - HI
    Below 1 Ω
    10 - 5 - 1
    A/C switch HI
    Below 1 Ω

  1. Text in Illustration 
    *a
    OFF
    *b
    LO
    *c
    M1
    *d
    M2
    *e
    HI
    *f
    Component without harness connected
    (heater control sub-assembly)



    E250316E02
  1. Check the heater control assembly resistance.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    2 - 4
    Rr DEF switch OFF
    10 kΩ or higher
    2 - 4
    Rr DEF switch ON
    Below 1 Ω

    Text in Illustration 
    *1
    Rr DEF switch
    *a
    Component without harness connected
    (heater control sub-assembly)

  1. Check that the Rr DEF switch illumination.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → 7
    Battery negative (-) → 5
    illuminates

  1. Check that the indicator light.

    Standard:
    Tester Connection
    Switch Condition
    Specified Condition
    Battery positive (+) → 6
    Battery negative (-) → 8
    Rr DEF switch OFF
    go out
    Battery positive (+) → 6
    Battery negative (-) → 8
    Rr DEF switch ON
    come on



3. INSPECT NO. 1 HEATER CONTROL SUB-ASSEMBLY


    E246510E02
  1. Check that the FRS switch illumination.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → 7
    Battery negative (-) → 6
    illuminates

    Text in Illustration 
    *1
    FRS switch
    *a
    Component without harness connected
    (No. 1 heater control sub-assembly)

  1. Check that the indicator light.

    Standard:
    Tester Connection
    Switch Condition
    Specified Condition
    Battery positive (+) → 5(LED+)
    Battery negative (-) → 4
    FRS switch OFF
    go out
    Battery positive (+) → 5(LED+)
    Battery negative (-) → 4
    FRS switch ON
    come on