FRONT BLOWER MOTOR > INSPECTION |
| 1. INSPECT BLOWER MOTOR |
![]() |
Disconnect the connector from the blower motor.
| *a | Component without harness connected (Blower Motor) |
| Measurement Condition | Specified Condition |
| Battery positive (+) → 2 Battery negative (-) → 1 | The blower motor operates smoothly |