Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR

SOLAR SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR


    E250277E01
  1. Disconnect the connector from the automatic light control sensor.
    Text in Illustration 
    *a
    Component with harness connected
    (automatic light control sensor)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1(TSD) - 6(CLTE)
    Solar sensor covered with a cloth.
    Below 0.8V
    Solar sensor exposed to electric light.
    4.0 to 4.6V

    HINT:
    Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the automatic light control sensor.

    If the resistance is not as specified, replace the automatic light control sensor.