Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Operating Light Control Rheostat does not Change Light Brightness

for Preparation Click here


DESCRIPTION

The brightness of the combination meter assembly is controlled by rotating the light control rheostat knob in upward and downward.

WIRING DIAGRAM


E246792E01


INSPECTION PROCEDURE

1.READ VALUE USING GTS (RHEOSTAT SWITCH)
  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. According to the display on the tester, read the Data List.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tail Cancel SW
    Light control rheostat switch (cancel switch) / OFF or ON
    OFF: Light control rheostat switch (cancel switch) → OFF
    -
    ON: Light control rheostat switch (cancel switch) → TAIL
    Rheostat value
    Light control rheostat switch input /
    Min.: 0
    Max.: 100
    Displays rheostat volume figure
    0 to 100
    -

    OK:
    The value displayed on the GTS changes in accordance with the actual rheostat switch operation.



NG
Go to step 2
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)  

2.INSPECT LIGHT CONTROL RHEOSTAT


  1. Remove the light control rheostat (Click here).


    E246793E01

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 6
    Cancel switch off → on
    10 kΩ or higher → Below 1 Ω
    4 - 6
    Always
    4475 to 4946 Ω
    5 - 6
    Light control rheostat fully up → Light control rheostat fully down
    485 to 536 Ω → 4380 to 4841 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Light Control Rheostat)



NG
REPLACE LIGHT CONTROL RHEOSTAT (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
  1. Disconnect the D7 combination meter assembly connector.

  1. Disconnect the D2 light control rheostat connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    D7-30 (E) - D2-6
    Always
    Below 1 Ω
    D7-31 (TR) - D2-5
    Always
    Below 1 Ω
    D7-32 (T) - D2-4
    Always
    Below 1 Ω
    D7-33 (TC) - D2-1
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    D7-30 (E) or D2-6 - Body ground
    Always
    10 kΩ or higher
    D7-31 (TR) or D2-5 - Body ground
    Always
    10 kΩ or higher
    D7-32 (T) or D2-4 - Body ground
    Always
    10 kΩ or higher
    D7-33 (TC) or D2-1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)