HAZARD WARNING SWITCH > INSPECTION |
| 1. INSPECT CLOCK ASSEMBLY |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 7 (HAZARD+) - 14 (HAZARD-) | Hazard warning signal switch off | 10 kΩ or higher |
| 7 (HAZARD+) - 14 (HAZARD-) | Hazard warning signal switch on | Below 1 Ω |
Apply battery voltage to the connector and check the LED illumination condition.
| Condition | Specified Condition |
| Battery positive (+) → 9 Battery negative (-) → 13 | LED illuminates |
| *a | Component without harness connected (Clock Assembly) |