DTC B27A6 Open in Rear Floor Electrical Key Oscillator Circuit |
| DTC Code | DTC Detection Condition | Trouble Area | DTC Output Confirmation Operation |
| B27A6 | An open circuit is detected in the circuit between the certification ECU (smart key ECU assembly) and No. 2 indoor electrical key oscillator (rear floor) (CLG6 - ANTE6, CG6B - CLGB) (1 trip detection logic*). |
| Any time |
| Vehicle Condition when Malfunction Detected | Fail-safe Operation when Malfunction Detected |
When electrical key transmitter sub-assembly is in rear seat area:
| - |
| DTC Code | Data List and Active Test |
| B27A6 | Key diagnostic mode can be used to perform troubleshooting |

| 1.CHECK CONNECTOR CONNECTION |
Turn the engine switch off.
Check that the connectors are properly connected to the certification ECU (smart key ECU assembly) and No. 2 indoor electrical key oscillator (rear floor).
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - NO. 2 INDOOR ELECTRICAL KEY OSCILLATOR) |
Disconnect the D40 and D48 certification ECU (smart key ECU assembly) connectors.
Disconnect the H15 No. 2 indoor electrical key oscillator (rear floor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D40-11 (CLG6) - H15-1 (ANTE6) | Always | Below 1 Ω |
| D40-10 (CG6B) - H15-3 (CLGB) | Always | Below 1 Ω |
| D48-11 (GND) - Body ground | Always | Below 1 Ω |
| D40-11 (CLG6) - Body ground | Always | 10 kΩ or higher |
| D40-10 (CG6B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (OUTPUT TO NO. 2 INDOOR ELECTRICAL KEY OSCILLATOR) |

| *a | Component with harness connected (Certification ECU (smart key ECU assembly)) | *b | Waveform |
| *c | Within approximately 30 seconds from when the door is closed | *d | After approximately 30 seconds from when the door is closed |
Reconnect the D40 and D48 certification ECU (smart key ECU assembly) connectors.
Reconnect the H15 No. 2 indoor electrical key oscillator (rear floor) connector.
Using an oscilloscope, check the waveform.
| Tester Connection | Switch Condition | Tool Setting | Specified Condition |
| D40-11 (CLG6) - D48-11 (GND) | Procedure:
| 2 V/DIV., 500 ms/DIV. | Pulse generation (See waveform) |
| D40-10 (CG6B) - D48-11 (GND) | Procedure:
| 2 V/DIV., 500 ms/DIV. | Pulse generation (See waveform) |
|
| ||||
| OK | |
| 4.REPLACE NO. 2 INDOOR ELECTRICAL KEY OSCILLATOR (REAR FLOOR) |
Temporarily replace the No. 2 indoor electrical key oscillator (rear floor) with a new or known good one (Click here).
| NEXT | |
| 5.CHECK FOR DTC |
Clear the DTCs (Click here)
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||