Home › Engine / Hybrid System › FA20 COOLING › THERMOSTAT (for Engine Coolant)

THERMOSTAT (for Engine Coolant) > INSPECTION

for Preparation Click here



1. INSPECT THERMOSTAT


    A104285
  1. Immerse the thermostat in water and then gradually heat the water.

    HINT:
    Hold the thermostat with a wire or the like, so that the thermostat does not come into contact with the bottom of the container.

  1. Check the valve opening temperature of the thermostat.

    Standard valve opening temperature:
    86 to 90 °C (187 to 194 °F)

    HINT:
    If the valve opening temperature is not as specified, replace the thermostat.

  1. Check the valve opening temperature.



    A282917E01
  1. Check the valve lift.
    Text in Illustration 
    *a
    Valve lift

    Valve lift:
    8.0 mm (0.315 in.) or more at 95 °C (203 °F)

    HINT:
    If the valve lift value is not as specified, replace the thermostat.

  1. When the temperature of the thermostat drops below 83 °C (181 °F), check that the valve is fully closed.

    HINT:
    If the valve is not fully closed, replace the thermostat.