Home › Engine / Hybrid System › FA20 ENGINE CONTROL › RELAY

RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT EFI MAIN 1 RELAY


    A167865E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to 1 and 2 terminals
    10 kΩ or higher
    Battery voltage applied to 1 and 2 terminals
    Below 1 Ω

    If the result is not as specified, replace the EFI main 1 relay.



2. INSPECT EFI MAIN 2 RELAY


    A167865E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to 1 and 2 terminals
    10 kΩ or higher
    Battery voltage applied to 1 and 2 terminals
    Below 1 Ω

    If the result is not as specified, replace the EFI main 2 relay.



3. INSPECT EFI MAIN 3 RELAY


    A167865E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to 1 and 2 terminals
    10 kΩ or higher
    Battery voltage applied to 1 and 2 terminals
    Below 1 Ω

    If the result is not as specified, replace the EFI main 3 relay.



4. INSPECT IG2 RELAY


    A167865E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to 1 and 2 terminals
    10 kΩ or higher
    Battery voltage applied to 1 and 2 terminals
    Below 1 Ω

    If the result is not as specified, replace the IG2 relay.



5. INSPECT INJ RELAY


    E209495
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to 1 and 2 terminals
    10 kΩ or higher
    Battery voltage applied to 1 and 2 terminals
    Below 1 Ω

    If the result is not as specified, replace the INJ relay.



6. INSPECT ETCS RELAY


    A167865E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to 1 and 2 terminals
    10 kΩ or higher
    Battery voltage applied to 1 and 2 terminals
    Below 1 Ω

    If the result is not as specified, replace the ETCS relay.



7. INSPECT C/OPEN RELAY


    A167865E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to 1 and 2 terminals
    10 kΩ or higher
    Battery voltage applied to 1 and 2 terminals
    Below 1 Ω

    If the result is not as specified, replace the C/OPEN relay.