COOLER EXPANSION VALVE > REMOVAL |
| 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
| 2. SEPARATE SUCTION HOSE SUB-ASSEMBLY |
![]() |
Remove the bolt and slide the hook connector.
Disconnect the suction hose sub-assembly.
Remove the O-ring from the suction hose sub-assembly.
| 3. SEPARATE AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY |
Disconnect the air conditioner tube and accessory assembly.
Remove the O-ring from the air conditioner tube and accessory assembly.
| 4. REMOVE COOLER EXPANSION VALVE |
![]() |
Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.
![]() |
Temporarily install the bolt for the suction hose sub-assembly halfway to the cooler expansion valve.
| *1 | Bolt For The Suction Tube Sub-assembly |
![]() |
Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.
![]() |
Remove the 2 O-rings from the evaporator pipe.
| *1 | Evaporator Pipe |