Home › Engine / Hybrid System › K3-VE ENGINE CONTROL › SFI SYSTEM › 2011.11–2015.08
NM19Y0E _51 Engine / Hybrid System _003173 K3-VE ENGINE CONTROL _0015998 SFI SYSTEM DE DETAILS F

K3-VE ENGINE CONTROL  SFI SYSTEM  DETAILS  KNOCK SENSOR  


CONSTRUCTION


a.

In a conventional knock sensor (resonant type), a vibration plate is built into the sensor. This plate has the same resonance point as the knocking frequency of the engine block. This sensor can only detect vibration in this frequency band.


b.

A flat type knock sensor (non-resonant type) has the ability to detect vibration in a wider frequency band (from about 6 kHz to 15 kHz). It has the following features.


c.

The engine knocking frequency will vary slightly depending on the engine speed. The flat type knock sensor can detect vibration even when the engine knocking frequency changes. Due to the use of the flat type knock sensor, the vibration detection ability is increased compared to a conventional type knock sensor, and more precise ignition timing control is possible.

W100530E12
3.438,2.927 3.948,2.49 3.948,2.49 4.073,2.49 true 3.406,1.823 3.917,1.396 3.917,1.396 4.052,1.396 true 0.146,0.125 3.208,0.583 3.063,0.458 12 Characteristic of KNOCK SENSOR : 0.906,0.677 4.854,1.083 3.948,0.406 10 : Resonance Characteristic of Conventional Type (Resonant) 0.906,0.99 4.719,1.344 3.813,0.354 10 : Resonance Characteristic of Flat Type (Non-resonant) 1.552,1.385 1.938,1.792 0.385,0.406 10 (V) 1.094,2.313 1.802,2.74 0.708,0.427 10 Voltage 3.083,3.396 3.938,3.75 0.854,0.354 10 Frequency 5.25,3.198 5.75,3.615 0.5,0.417 10 (Hz) 4.125,2.417 6.073,2.865 1.948,0.448 10 Detection Band of Flat Type 4.115,1.333 6.74,1.854 2.625,0.521 10 Detection Band of Resonant Type


d.

A flat type knock sensor is installed to an engine by placing it over the stud bolt installed on the cylinder block sub-assembly. For this reason, a hole for the stud bolt exists in the center of the sensor.


e.

In the sensor, a steel weight is located in the upper portion. An insulator is located between the weight and a piezoelectric element.


f.

An open/short circuit detection resistor is integrated in the sensor. When the ignition is ON, the open/short circuit detection resistor in the knock sensor and the resistor in the ECM keep the voltage at terminal KNK constant. An Integrated Circuit (IC) in the ECM constantly monitors the voltage of terminal KNK. If the open/short circuit occurs between the knock sensor and the ECM, the voltage of terminal KNK will change and the ECM will detect the open/short circuit and store a Diagnostic Trouble Code (DTC).

W100954C05
1.083,1.958 0.958,1.24 0.958,1.24 0.865,1.24 true 1.125,1.875 0.958,0.604 0.958,0.604 0.865,0.604 true 1.167,1.771 1.323,0.531 1.323,0.531 1.427,0.531 true 2.313,1.958 2.406,0.75 2.406,0.75 2.521,0.75 true 5.688,1.542 6.104,0.792 6.104,0.792 6.208,0.792 true 5.76,1.563 6.135,1.948 6.135,1.948 6.219,1.948 true 0.667,1.177 1.052,1.583 0.385,0.406 10 *c 0.667,0.51 1.042,0.917 0.375,0.406 10 *b 1.469,0.458 1.865,0.854 0.396,0.396 10 *a 2.583,0.656 3.01,1.177 0.427,0.521 10 *d 0.333,0.135 0.771,0.469 0.438,0.333 12 *A 4.792,0.135 5.208,0.49 0.417,0.354 12 *B 6.281,0.719 6.646,1.115 0.365,0.396 10 *c 6.281,1.875 6.667,2.292 0.385,0.417 10 *e
*A Flat Type Knock Sensor
(Non-resonant Type)
*B Conventional Type Knock Sensor
(Resonant Type)
*a Steel Weight *b Insulator
*c Piezoelectric Element *d Open Circuit Detection Resistor
*e Vibration Plate - -


W103585E04
1.479,1.448 1.979,2.406 1.979,2.406 2.167,2.406 true 2.115,1.438 2.5,2.135 2.5,2.135 2.635,2.135 true 0.719,0.417 2.76,0.823 2.042,0.406 10 Flat Type KNOCK SENSOR 4.052,0.875 4.583,1.292 0.531,0.417 10 KNK 4.167,1.521 4.521,1.927 0.354,0.406 10 E2 5.094,1.323 5.677,1.781 0.583,0.458 10 ECM 2.229,1.323 2.917,1.635 0.688,0.313 10 200kΩ 2.708,2.052 5.281,2.531 2.573,0.479 10 Open/Short Circuit Detection Resistor 2.25,2.323 3.865,2.781 1.615,0.458 10 Piezoelectric Element


g.

Vibrations caused by knocking are transmitted to the steel weight. The inertia of this weight applies pressure to the piezoelectric element. This action generates electromotive force.

W101072C05
3.594,1.302 2.917,1.167 2.917,1.167 2.823,1.167 true 3.542,0.99 2.938,0.292 2.938,0.292 2.865,0.292 true 3.594,1.135 4.406,0.719 4.406,0.719 4.49,0.719 true 2.604,1.083 2.979,1.583 0.375,0.5 10 *b 4.573,0.635 4.938,1.042 0.365,0.406 10 *c 2.667,0.188 3.094,0.667 0.427,0.479 10 *a
*a Steel Weight *b Piezoelectric Element
*c Inertia - -