Home › Engine / Hybrid System › 2NR-VE ENGINE CONTROL › SFI SYSTEM › from 2015.08
NM19Y0E _51 Engine / Hybrid System _041612 2NR-VE ENGINE CONTROL _0198970 SFI SYSTEM DE DETAILS F

2NR-VE ENGINE CONTROL  SFI SYSTEM  DETAILS  COOLING FAN CONTROL  


OPERATION


a.

The ECM calculates the cooling fan speed in accordance with the engine coolant temperature and air conditioning operating conditions, and sends signals to the No. 1 integration relay. Upon receiving the signals from the ECM, the No. 1 integration relay actuates the cooling fan motor.

W129699E01
5.646,0.99 5.833,0.365 5.833,0.365 6.063,0.365 true 0.552,1.177 2.99,1.531 2.438,0.354 10 false Engine Coolant Temperature Sensor 0.615,3.563 2.115,3.917 1.5,0.354 10 false No. 1 Cooler Thermistor 3.042,3.427 4.458,4.063 1.417,0.635 10 false Main Body ECU (Fuse Block Assembly) 4.583,1.396 5.292,2.385 0.708,0.99 10 false No. 1 Integration Relay 3.615,1.688 4.073,1.885 0.458,0.198 10 false ECM 6.115,0.281 7.104,0.771 0.99,0.49 10 false Cooling Fan Resistor* 6.323,2.031 7.115,2.719 0.792,0.688 10 false Cooling Fan Motor 3.208,4.219 5.625,4.531 2.417,0.313 10 false *: Models with Cooling Fan Resistor 0.677,4.208 2.479,4.667 1.802,0.458 10 false : CAN Communication Line 0.708,2.146 2.688,2.5 1.979,0.354 10 false Airconditioner Pressure Sensor