OUTLINE
The air conditioning system main components have been made compact, lightweight, and highly efficient to realize a combination of ensuring comfort and enhancing actual fuel consumption.
SPECIFICATIONS
Air Conditioning Unit Assembly
|
*1: Models with heater *2: Models except Thailand, Malaysia and tropic *3: Models for Thailand, Malaysia or tropic *4: Models except Thailand and Malaysia *5: Models for Thailand or Malaysia |
||
| Heater Radiator*1 | Type | Straight Flow Aluminum (SFA)-II |
| Size (Width x Height x Thickness) | 211.9 mm x 120.0 mm x 21.0 mm
(8.3 in. x 4.7 in. x 0.9 in.) |
|
| Fin Pitch | 1.8 mm (0.07 in.) | |
| Evaporator | Type | Revolutionary super-slim Structure (RS) |
| Size (Width x Height x Thickness)*2 | 226.1 mm x 191.0 mm x 38.0 mm
(8.9 in. x 7.1 in. x 1.5 in.) |
|
| Size (Width x Height x Thickness)*3 | 226.1 mm x 231.0 mm x 38.0 mm
(8.9 in. x 9.1 in. x 1.5 in.) |
|
| Fin Pitch | 3.0 mm (0.1 in.) | |
| Blower Motor | Motor Type | K62F-12.5T*4
4PS-24T*5 |
| Fan Type | Shroud Sirocco | |
| Fan Size (Diameter x Height) | 145.0 mm x 65.0 mm (5.7 in. x 2.6 in.) | |
Rear Cooling Unit Assembly
| Evaporator | Type | Plate Fin |
| Size (Width x Height x Thickness) | 300.0 mm x 96.9 mm x 40.0 mm
(11.8 in. x 3.8 in. x 1.6 in.) |
|
| Fin Pitch | 1.8 mm (0.1 in.) | |
| Blower Motor | Motor Type | S50FS-38T |
| Fan Type | Cross Flow | |
| Fan Size (Diameter x Height) | 62.0 mm x 301.0 mm (2.4 in. x 11.9 in.) |
Cooler Condenser Assembly
|
*1: Models except tropic *2: Models for tropic |
|
| Type | Global Inner-fin Condenser (GIC) |
| Size (Width x Height x Thickness)*1 | 460.0 mm x 376.2 mm x 11.5 mm
(18.1 in. x 14.8 in. x 0.5 in.) |
| Size (Width x Height x Thickness)*2 | 520.0 mm x 440.2 mm x 11.5 mm
(20.5 in. x 17.3 in. x 0.5 in.) |
| Fin Pitch | 2.5 mm (0.1 in.) |
Compressor and Magnetic Clutch
|
*1: Models except tropic *2: Models for tropic |
|
| Type | 10SA13C*1
10S15C*2 |
Refrigerant
| Type | HFC-134a |
MAIN FEATURES
The air conditioning system has the following features:
| High Performance | ·
The blower control has 4 steps to allow precise control. ·
The roof fan (rear cooling unit assembly) is used. This fan sends air from the center register to the rear seats. |
| Others | The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction.
·
Semi-center location air conditioning unit ·
Revolutionary super-slim Structure (RS) evaporator ·
Straight Flow Aluminum (SFA)-II heater radiator unit sub-assembly ·
Global Inner-fin Condenser (GIC) |