Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2015.08
NM19Y0E _58 Vehicle Interior _003212 HEATING / AIR CONDITIONING _0016041 AIR CONDITIONING SYSTEM DE DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DETAILS  COOLER CONDENSER  


CONSTRUCTION


a.

A Global Inner-fin Condenser (GIC) is provided. This condenser has tubes with high-density inner fins, and outer fins which allow the use of thinner cores, contributing to the efficiency of cooling performance.

Y183604C02
1.885,0.927 1.667,0.427 true 5.208,0.927 5.292,0.74 true 5.094,2.385 5.177,2.198 true 5.417,2.906 5.542,3.156 true 1.531,0.25 1.844,0.448 0.313,0.198 10 false *1 5.292,0.573 5.604,0.771 0.313,0.198 10 false *2 4.938,2.406 5.25,2.604 0.313,0.198 10 false *3 5.542,3.177 5.854,3.375 0.313,0.198 10 false *4 4.927,3.104 5.24,3.302 0.313,0.198 10 false *a 4.177,1.156 4.385,1.354 0.208,0.198 10 true A 5.125,1.177 5.333,1.375 0.208,0.198 10 true A
*1 Cooler Condenser Assembly *2 Tube (Inner Fin)
*3 Outer Fin *4 Fin Louver
*a A - A Cross Section - -



b.

The cooler condenser assembly consists of 2 cooling portions: a condensing portion and a super-cooling portion. These portions are integrated with a gas-liquid separator (modulator). This cooler condenser assembly uses a sub-cool cycle that offers excellent heat-exchange performance.


c.

In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.


d.

The desiccant and filter at the bottom of the modulator remove moisture and debris from the refrigerant.

Y183603C01
4.292,1.188 4.698,0.563 4.698,0.563 4.938,0.563 true 5.438,1.688 5.688,1.688 true 5.365,2.031 5.688,2.031 true 4.99,0.5 5.302,0.698 0.313,0.198 10 false *1 5.729,1.969 6.042,2.167 0.313,0.198 10 false *3 5.729,1.615 6.042,1.813 0.313,0.198 10 false *2
*1 Modulator *2 Desiccant
*3 Filter - -
V100137

Gaseous Refrigerant
V100135

Condensing Portion
V100136

Super-cooling Portion
V100138

Liquid Refrigerant


HINT:

The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system is recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant will be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to reduced performance. For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, refer to the Repair Manual.