89421B
1.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR
| *a | Front view of wire harness connector
(to Vacuum Sensor) |
Inspect the power source voltage.
Disconnect the vacuum sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 (VC) - 1 (-) | Ignition switch ON | 4.5 to 5.5 V |
Turn the ignition switch off.
Reconnect the vacuum sensor connector.
Check the vacuum and pressure.
Connect the intelligent tester or Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester or Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAP.
| Tester Display |
|---|
| MAP |
Read the MAP value.
| Condition | Specified Condition |
|---|---|
| No pressure applied | Same as atmospheric pressure |
| Vacuum applied | Indicates vacuum |
| Pressure applied | Indicates pressure |
If the result is not as specified, replace the vacuum sensor.