89465
1.INSPECT HEATED OXYGEN SENSOR (for Sensor 1)
| *1 | for LHD |
| *2 | for RHD |
| *a | Component without harness connected
(Heated Oxygen Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (OXH2) - 2 (+B) | 20°C (68°F) | 11.7 to 15.5 Ω |
| 1 (OXH2) - 4 (E2) | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (IREL) - 2 (ECHI) | 20°C (68°F) | 11.7 to 15.5 Ω |
| 1 (IREL) - 4 (E) | Always | 10 kΩ or higher |
If the result is not as specified, replace the sensor.
89465A
2.INSPECT HEATED OXYGEN SENSOR (for Sensor 2)
| *A | for LHD |
| *B | for RHD |
| *a | Component without harness connected
(Heated Oxygen Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HTR-) - 2 (HTR+) | 20°C (68°F) | 11.7 to 15.5 Ω |
| 1 (HTR-) - 4 (E) | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HTR-) - 2 (HTR+) | 20°C (68°F) | 11.7 to 15.5 Ω |
| 1 (HTR-) - 4 (E) | Always | 10 kΩ or higher |
If the result is not as specified, replace the sensor.