Home › Engine / Hybrid System › 3SZ-VE ENGINE CONTROL › HEATED OXYGEN SENSOR(w/ Rear Heated Oxygen Sensor) › 2011.11–2015.08
RM19Y0E _51 Engine / Hybrid System _002968 3SZ-VE ENGINE CONTROL _0014990 HEATED OXYGEN SENSOR(w/ Rear Heated Oxygen Sensor) G

3SZ-VE ENGINE CONTROL  HEATED OXYGEN SENSOR(w/ Rear Heated Oxygen Sensor)  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR (for Sensor 1)

a.
A241677C01
2,0.896 2.417,0.896 true 0.927,1.333 1.333,1.333 true 1,0.708 1.333,0.906 true 2.51,0.99 3.177,1.333 0.667,0.344 10 IREL*2 2.5,0.823 3.281,1.198 0.781,0.375 10 OXH2*1 0.365,0.615 1.135,0.938 0.771,0.323 10 ECHI*2 0.365,0.448 1.01,0.729 0.646,0.281 10 +B*1 0.146,0.104 0.76,0.479 0.615,0.375 10 *a 0.5,1.427 1,1.719 0.5,0.292 10 E*2 0.5,1.26 1.167,1.531 0.667,0.271 10 E2*1
*1 for LHD
*2 for RHD
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance (for LHD):
Tester Connection Condition Specified Condition
1 (OXH2) - 2 (+B) 20°C (68°F) 11.7 to 15.5 Ω
1 (OXH2) - 4 (E2) Always 10 kΩ or higher


Standard Resistance (for RHD):
Tester Connection Condition Specified Condition
1 (IREL) - 2 (ECHI) 20°C (68°F) 11.7 to 15.5 Ω
1 (IREL) - 4 (E) Always 10 kΩ or higher


If the result is not as specified, replace the sensor.



Hide 89465A 2.INSPECT HEATED OXYGEN SENSOR (for Sensor 2)

a.
A268887C01
1.167,0.656 1.51,0.771 true 1.167,1.333 1.51,1.229 true 2.375,0.656 2.031,0.771 true 1.167,2.271 1.51,2.385 true 1.167,2.948 1.51,2.833 true 2.375,2.271 2.031,2.385 true 2.469,0.573 3.073,0.969 0.604,0.396 10 HTR- 0.76,0.583 1.406,0.969 0.646,0.385 10 HTR+ 1.021,1.344 1.417,1.667 0.396,0.323 10 E 0.146,0.115 0.729,0.531 0.583,0.417 12 *A 0.146,1.792 0.583,2.115 0.438,0.323 12 *B 2.438,2.177 3.063,2.51 0.625,0.333 10 HTR- 0.75,2.177 1.531,2.625 0.781,0.448 10 HTR+ 1,2.917 1.406,3.208 0.406,0.292 10 E 0.938,0.167 1.344,0.531 0.406,0.365 10 *a 0.938,1.854 1.417,2.167 0.479,0.313 10 *a
*A for LHD
*B for RHD
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance (for LHD):
Tester Connection Condition Specified Condition
1 (HTR-) - 2 (HTR+) 20°C (68°F) 11.7 to 15.5 Ω
1 (HTR-) - 4 (E) Always 10 kΩ or higher


Standard Resistance (for RHD):
Tester Connection Condition Specified Condition
1 (HTR-) - 2 (HTR+) 20°C (68°F) 11.7 to 15.5 Ω
1 (HTR-) - 4 (E) Always 10 kΩ or higher