Home › Engine / Hybrid System › 3SZ-VE EMISSION CONTROL › CANISTER › 2011.11–2015.08
RM19Y0E _51 Engine / Hybrid System _002973 3SZ-VE EMISSION CONTROL _0015026 CANISTER A

3SZ-VE EMISSION CONTROL  CANISTER  INSTALLATION  


PROCEDURE

Hide 77740 1.INSTALL CHARCOAL CANISTER ASSEMBLY

A268981C03
2,1.865 2.25,1.865 false 2.292,1.781 2.479,1.938 0.188,0.156 10 *1 0.146,0.094 0.333,0.25 0.188,0.156 10 *a 1.125,0.375 1.333,0.552 0.208,0.177 10 *b 2.021,0.365 2.229,0.552 0.208,0.188 10 *c 1.625,2.635 1.813,2.792 0.188,0.156 10 *d 0.958,3.229 1.146,3.385 0.188,0.156 10 *e 2.552,3.24 2.938,3.396 0.385,0.156 10 90°
*1 Charcoal Canister Assembly
*a Canister Side
*b 0 to 2 mm (0 to 0.08 in.)
*c 2 to 5 mm (0.08 to 0.2 in.)
*d Up
*e Left


a.

Install the charcoal canister assembly.


b.

Connect the evapo hose to the charcoal canister assembly.


c.

Connect the charcoal canister hose and No. 2 charcoal canister outlet hose to the charcoal canister assembly.

NOTICE:

Install the clip as illustrated.