Home › Engine / Hybrid System › 3SZ-VE EMISSION CONTROL › CANISTER › 2011.11–2015.08
RM19Y0E _51 Engine / Hybrid System _002973 3SZ-VE EMISSION CONTROL _0015026 CANISTER G

3SZ-VE EMISSION CONTROL  CANISTER  INSPECTION  


PROCEDURE

Hide 77740 1.INSPECT CHARCOAL CANISTER ASSEMBLY

a.

Check the appearance.

i.
A143439

Visually check whether the portions of the charcoal canister assembly indicated with the arrows are cracked or damaged.

If necessary, replace the charcoal canister assembly.



b.

Check the ventilation.

i.
A285405C03
1.677,0.021 1.833,0.219 0.156,0.198 10 A 1.354,0.667 1.51,0.865 0.156,0.198 10 B 1.99,0.729 2.146,0.927 0.156,0.198 10 C 2.344,0.042 2.656,0.24 0.313,0.198 10 *a
*a Air


Blow air (5.9 kPa (0.06 kgf/cm2, 0.86 psi)) into port A, then check that the air flows from port B while holding port C closed.

If the ventilation is not as specified, replace the charcoal canister assembly.


ii.
A285406C03
1.646,0.052 1.802,0.25 0.156,0.198 10 A 1.354,0.698 1.51,0.896 0.156,0.198 10 B 2.156,0.542 2.313,0.74 0.156,0.198 10 C 2.344,0.073 2.656,0.271 0.313,0.198 10 *a
*a Air


Blow air (5.9 kPa (0.06 kgf/cm2, 0.86 psi)) into port A, then check that the air flows from ports B and C.

If the ventilation is not as specified, replace the charcoal canister assembly.


iii.
A285407C03
1.135,0.042 1.292,0.24 0.156,0.198 10 A 0.906,0.75 1.063,0.948 0.156,0.198 10 B 1.604,0.74 1.76,0.938 0.156,0.198 10 C 2.406,1.177 2.719,1.375 0.313,0.198 10 *a
*a Vacuum


Apply a vacuum (2.9 kPa (21.8 mmHg, 0.86 in.Hg)) to port A, then check that the vacuum does not decrease when ports B and C are closed, and check that the vacuum decreases when port B is released.

If the ventilation is not as specified, replace the charcoal canister assembly.



c.

Clean the filter in the charcoal canister assembly.

i.
A285408C03
1.635,0.063 1.792,0.26 0.156,0.198 10 A 1.344,0.417 1.656,0.615 0.313,0.198 10 *a 1.333,0.76 1.49,0.958 0.156,0.198 10 B 2.167,0.531 2.323,0.729 0.156,0.198 10 C
*a Air


Clean the filter by blowing (19.6 kPa (0.2 kgf/cm2, 2.8 psi)) compressed air into port B while holding port A closed.

NOTICE:
·

Do not attempt to wash the charcoal canister assembly.

·

Do not allow activated carbon to come out.