16331A
1.INSPECT THERMOSTAT
The thermostat is imprinted with the valve opening temperature.
Check that the jiggle pin moves smoothly.
Immerse the thermostat in water, then gradually heat the water.
Before heating the thermostat, measure the valve length with the valve fully closed.
Check the valve opening temperature.
78 to 82°C (172 to 180°F)
If the valve opening temperature is not as specified, replace the thermostat.
| *a | Valve Lift |
Check the valve lift at higher temperatures.
8.5 mm (0.335 in.) or more (at 93°C (199°F))
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat is at low temperatures (77°C (171°F) or below).
If not fully closed, replace the thermostat.