Home › Engine / Hybrid System › 3SZ-VE COOLING › THERMOSTAT › 2011.11–2015.08
RM19Y0E _51 Engine / Hybrid System _002978 3SZ-VE COOLING _0015055 THERMOSTAT G

3SZ-VE COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16331A 1.INSPECT THERMOSTAT

A143088

HINT:

The thermostat is imprinted with the valve opening temperature.


a.

Check that the jiggle pin moves smoothly.


b.
A143089

Immerse the thermostat in water, then gradually heat the water.

NOTICE:

Before heating the thermostat, measure the valve length with the valve fully closed.



c.

Check the valve opening temperature.

Valve opening temperature:

78 to 82°C (172 to 180°F)


If the valve opening temperature is not as specified, replace the thermostat.


d.
A143090C01
2.458,1.604 2.865,1.979 0.406,0.375 10 *a
*a Valve Lift


Check the valve lift when it gets even hotter.

Valve lift:

8.5 mm (0.335 in.) or more (at 93°C (199°F))


If the valve lift is not as specified, replace the thermostat.


e.

Check that the valve is fully closed when the thermostat is at low temperatures (77°C (171°F) or below).

If not fully closed, replace the thermostat.