The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input to the TCM.
The sensor resistance changes with the transmission fluid temperature. As the temperature rises, the sensor resistance decreases. The TCM applies a voltage to the temperature sensor through TCM terminal OTMP, and the TCM calculates the fluid temperature based on the voltage signal.
The ATF temperature is likely to increase under conditions such as towing, climbing hills and in heavy traffic.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Memory |
|---|---|---|---|---|---|---|
| P0710 | Transmission Fluid Temperature Sensor "A" Circuit | ATF temperature sensor circuit becomes open or short for a specific period of time.
(1 trip detection logic) |
·
Open or short in ATF temperature sensor circuit ·
Solenoid wire (ATF temperature sensor) ·
TCM |
Come on | Blinks | DTC stored |
| P0711 | Transmission Fluid Temperature Sensor Circuit Range / Performance | ATF temperature sensor does not operate correctly.
(2 trip detection logic) |
·
Solenoid wire (ATF temperature sensor) ·
TCM |
Come on | Blinks | DTC stored |
MIL:"Comes on" means the MIL (Malfunction IndicatorLamp) illuminates.
Memory:"DTC stored" means the TCM stores the trouble code if the ECU detects the DTC detection condition.
| *a | Front view of wire harness connector
(to Solenoid wire) |
Disconnect the E21 solenoid wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition(ATF Temperature) | Specified Condition |
|---|---|---|
| 8 (H5) - 12 (H9) | 0°C (32°F) | 5.07 kΩ to 6.19 kΩ |
| 140°C (284°F) | 69.8 Ω to 74.2 Ω | |
| 8 (H5) or 12 (H9) - Body ground | - | 10 kΩ or higher |
If the resistance is outside the specified range at either of the ATF temperatures shown in the table below, the driveability of the vehicle may be affected.
| ATF Temperature | Specified Condition |
|---|---|
| 20°C (68°F) | 2.4 kΩ |
| 80°C (176°F) | 313 Ω |
Reconnect the E3 solenoid wire connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E10 TCM connector.
Measure the resistance.
| Tester Connection | Condition(ATF Temperature) | Specified Condition |
|---|---|---|
| E10-14 (OTMP) - E10-13 (ETMP) | 0°C (32°F) | 5.07 kΩ to 6.19 kΩ |
| 140°C (284°F) | 69.8 Ω to 74.2 Ω | |
| E10-14 (OTMP) or E10-13 (ETMP) - Body ground | - | 10 kΩ or higher |
If the resistance is outside the specified range at either of the ATF temperatures shown in the table below, the driveability of the vehicle may be affected.
| ATF Temperature | Specified Condition |
|---|---|
| 20°C (68°F) | 2.4 kΩ |
| 80°C (176°F) | 313 Ω |
Reconnect the E10 TCM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG