NETWORKING  CAN COMMUNICATION SYSTEM  TERMINALS OF ECU  


NOTICE:
·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).

·

Turn the ignition switch off before measuring the resistances between CAN main bus lines and between CAN branch lines.

·

Turn the ignition switch off before inspecting CAN bus lines for a ground short.

·

Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

This section describes the standard values for all CAN related components.



HINT:
·

Operating the ignition switch, any other switches or a door triggers related ECU communication on the CAN. This communication will cause the resistance value to change.

·

Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.



CAN NO. 1 JUNCTION CONNECTOR*1 *2


*1 : for A/T

*2 : w/ Multi Information Display

a.

Check the CAN No. 1 junction connector.

HINT:

The following tables contain information about the items and buses connected via junction connectors. The junction connector may be used for multiple separate buses. In this case, the name of the bus will be shown below the name of the item that terminals are connected to. The bus name will be shown in brackets (example: (for V bus)).


i.
C243541C04
0.271,0.74 0.76,1.031 0.49,0.292 2.25,1.073 2.594,1.521 true 2.604,0.292 2.26,0.74 true 1.479,0.302 1.833,0.75 true 2.073,1.063 2.625,1.781 true 1.646,1.063 1.302,1.521 true 1.813,1.063 1.271,1.781 true 0.094,0.073 0.604,0.406 0.51,0.333 10 *a 2.646,0.219 3.188,0.802 0.542,0.583 10 *b 1.271,0.219 2.083,0.729 0.813,0.51 10 *b 2.656,1.438 3.313,1.865 0.656,0.427 10 *c 2.667,1.719 3.219,2.031 0.552,0.313 10 *d 1.073,1.729 1.615,2.031 0.542,0.302 10 *c 1.073,1.458 1.677,1.823 0.604,0.365 10 *d 0.385,0.802 1.281,1.417 0.896,0.615 10 E45
*a Rear view of wire harness connector
(to CAN No. 1 Junction Connector)
*b to Combination Meter Assembly
(for V bus)
*c to ECM
(for V bus)
*d to TCM
(for V bus)


Connection diagram


ii.

Check the connection diagram of the components which are connected to the CAN No. 1 junction connector.

Terminal No. Wiring Color Connected to (Applicable Bus)
E45-1 B Combination meter assembly
(for V bus)
E45-3 W
E45-8 R ECM
(for V bus)
E45-10 G
E45-9 P TCM
(for V bus)
E45-11 LG




DLC3


E231257C11
1.448,0.26 1.938,0.552 0.49,0.292 2.365,1.479 2.615,1.927 true 2.24,0.458 1.99,0.917 true 1.302,0.469 1.552,0.927 true 1.906,1.49 1.656,1.938 true 0.104,0.094 0.76,0.656 0.656,0.563 10 *a 2.323,0.385 3.021,0.875 0.698,0.49 10 CANH 1.146,0.385 1.729,0.844 0.583,0.458 10 E 2.698,1.865 3.25,2.177 0.552,0.313 10 +B 1.177,1.865 1.896,2.125 0.719,0.26 10 CANL 1.573,0.323 2.167,0.729 0.594,0.406 10 E12
*a Front view of DLC3


a.

Disconnect the cable from the negative (-) battery terminal.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
E12-6 (CANH) - E12-14 (CANL) B - W HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) battery terminal 54 to 69 Ω
E12-6 (CANH) - E12-4 (E) B - W-B HIGH-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E12-14 (CANL) - E12-4 (E) W - W-B LOW-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E12-6 (CANH) - E12-16 (+B) B - W-B HIGH-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher
E12-14 (CANL) - E12-16 (+B) W - W-B LOW-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher




ECM


C243552C02
3.323,0.042 3.719,0.281 0.396,0.24 1.677,0.042 2.073,0.281 0.396,0.24 5.219,0.042 5.615,0.281 0.396,0.24 3.396,0.094 4.208,0.708 0.813,0.615 10 C24 1.75,0.094 2.531,0.531 0.781,0.438 10 C23 5.323,0.094 6.115,0.698 0.792,0.604 10 E3
*a Component without harness connected
(ECM)
- -


a.
C243553C02
1.104,0.375 1.594,0.667 0.49,0.292 1.885,0.375 2.375,0.667 0.49,0.292 2.583,1.063 2.292,1.167 true 2.583,1.354 2.292,1.25 true 1.333,1.396 1.563,2.021 true 2.219,1.156 2.583,0.823 true 0.094,0.073 0.531,0.49 0.438,0.417 10 *a 1.219,0.427 1.76,0.927 0.542,0.5 10 C24 2.031,0.427 2.677,0.896 0.646,0.469 10 E3 2.667,0.99 3.427,1.396 0.76,0.406 10 1 (LCAN) 2.667,1.302 3.427,1.729 0.76,0.427 10 7 (BAT) 1.646,1.958 2.365,2.177 0.719,0.219 10 32 (E1) 2.656,0.74 3.375,1.094 0.719,0.354 10 2 (HCAN)
*a Rear view of wire harness connector
(to ECM)


Disconnect the cable from the negative (-) battery terminal.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (V Bus Branch Lines):
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
E3-2 (HCAN) - E3-1 (LCAN) B - W HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) battery terminal 54 to 69 Ω
E3-2 (HCAN) - C24-32 (E1) B - W-B HIGH-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E3-1 (LCAN) - C24-32 (E1) W - W-B LOW-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E3-2 (HCAN) - E3-7 (BAT) B - B HIGH-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher
E3-1 (LCAN) - E3-7 (BAT) W - B LOW-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher



c.

Disconnect the cable from the negative (-) battery terminal.


d.
C243544C02
1.125,1.135 1.615,1.427 0.49,0.292 1.896,1.135 2.385,1.427 0.49,0.292 2.604,2.5 2.313,2.396 true 2.406,1.719 2.167,2.323 true 1.906,1.813 2.094,2.313 true 1.354,2.563 1.583,3.188 true 0.083,0.073 0.792,0.417 0.708,0.344 10 *a 1.24,1.208 1.792,1.677 0.552,0.469 10 C24 2.042,1.208 2.771,1.698 0.729,0.49 10 E3 2.677,2.438 3.292,2.823 0.615,0.385 10 7 (BAT) 2.49,1.625 3.219,2.094 0.729,0.469 10 3 (CANL) 1.25,1.688 2.021,2.104 0.771,0.417 10 4 (CANH) 1.667,3.115 2.458,3.375 0.792,0.26 10 32 (E1)
*a Rear view of wire harness connector
(to ECM)


Disconnect the C24 and E3 ECM connectors.


e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (V Bus Main Lines):
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
E3-4 (CANH) - E3-3 (CANL) R - G HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) battery terminal 108 to 132 Ω
E3-4 (CANH) - C24-32 (E1) R - W-B HIGH-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E3-3 (CANL) - C24-32 (E1) G - W-B LOW-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E3-4 (CANH) - E3-7 (BAT) R - B HIGH-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher
E3-3 (CANL) - E3-7 (BAT) G - B LOW-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher




TCM*


* : for A/T

C268830C03
2.646,0.083 3.042,0.333 0.396,0.25 4.229,0.083 4.625,0.333 0.396,0.25 2.75,0.135 3.417,0.604 0.667,0.469 10 E9 4.302,0.135 4.969,0.604 0.667,0.469 10 E10 0.135,0.083 0.583,0.438 0.448,0.354 10 *a
*a Component without harness connected
(TCM)
- -


a.

Disconnect the cable from the negative (-) battery terminal.


b.
C243543C06
1.146,0.583 1.635,0.875 0.49,0.292 1.625,2.26 1.969,2.719 true 2.021,2.052 1.625,2.188 true 2.219,1.76 1.427,2.104 true 0.885,1.646 1.25,2.115 true 0.094,0.083 0.667,0.74 0.573,0.656 10 *a 1.302,0.635 1.76,1.146 0.458,0.51 10 E9 2.104,1.99 2.896,2.417 0.792,0.427 10 7 (CANH) 2.052,2.667 3,2.99 0.948,0.323 10 17 (CANL) 2.292,1.635 2.948,1.958 0.656,0.323 10 3 (+B) 0.344,1.542 1.052,2.063 0.708,0.521 10 5 (E02)
*a Rear view of wire harness connector
(to ECM)


Disconnect the E9 TCM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (V Bus Main Lines*1):
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
E9-7 (CANH) - E9-17 (CANL) R - G HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) battery terminal 108 to 132 Ω
E9-7 (CANH) - E9-5 (E02) R - BR HIGH-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E9-17 (CANL) - E9-5 (E02) G - BR LOW-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E9-7 (CANH) - E9-3 (+B) R - L HIGH-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher
E9-17 (CANL) - E9-3 (+B) G - L LOW-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher


Standard Resistance (V Bus Branch Lines*2):
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
E9-7 (CANH) - E9-17 (CANL) P - LG HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) battery terminal 54 to 69 Ω
E9-7 (CANH) - E9-5 (E02) P - BR HIGH-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E9-17 (CANL) - E9-5 (E02) LG - BR LOW-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E9-7 (CANH) - E9-3 (+B) P - L HIGH-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher
E9-17 (CANL) - E9-3 (+B) LG - L LOW-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher


*1 : w/o Multi Information Display

*2 : w/ Multi Information Display



COMBINATION METER ASSEMBLY*


C243554C02
1.469,0.177 1.958,0.469 0.49,0.292 0.094,0.01 0.583,0.5 0.49,0.49 10 *a 1.583,0.24 2.063,0.615 0.479,0.375 10 E34
*a Component without harness connected
(Combination Meter Assembly)


* : w/ Multi Information Display

a.

Disconnect the cable from the negative (-) battery terminal.


b.
C243545C08
1.417,0.615 1.906,0.906 0.49,0.292 1.188,2.375 0.896,2.26 false 1.823,2.167 1.583,2.771 true 1.917,2.167 2.146,2.771 true 0.844,1.615 1.26,2.042 true 0.948,2.177 0.667,2.469 true 0.125,0.115 0.563,0.698 0.438,0.583 10 *a 1.531,0.698 2.281,1.448 0.75,0.75 10 E34 0.125,2.396 0.75,2.813 0.625,0.417 10 40 (+B) 0.854,2.688 1.833,3.219 0.979,0.531 10 29 (CANL) 2.25,2.677 3.177,3.188 0.927,0.51 10 28 (CANH) 0.396,1.521 1.177,2.094 0.781,0.573 10 16 (E)
*a Rear view of wire harness connector
(to Combination Meter Assembly)


Disconnect the E34 combination meter assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (V Bus Main Lines):
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
E34-28 (CANH) - E34-29 (CANL) B - W*1
R - G*2
HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) battery terminal 108 to 132 Ω
E34-28 (CANH) - E34-16 (E) B - BR*1
R - BR*2
HIGH-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E34-29 (CANL) - E34-16 (E) W - BR*1
G - BR*2
LOW-level CAN bus line - Ground Cable disconnected from negative (-) battery terminal 200 Ω or higher
E34-28 (CANH) - E34-40 (+B) B - B-W*1
R - B-W*2
HIGH-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher
E34-29 (CANL) - E34-40 (+B) W - B-W*1
G - B-W*2
LOW-level CAN bus line - Battery positive (+) Cable disconnected from negative (-) battery terminal 6 kΩ or higher


*1 : for A/T

*2 : for M/T