Home › Vehicle Interior › DOOR LOCK › WIRELESS DOOR LOCK CONTROL SYSTEM › 2011.11–2015.08
RM19Y0E _58 Vehicle Interior _003005 DOOR LOCK _0015187 WIRELESS DOOR LOCK CONTROL SYSTEM M

DOOR LOCK  WIRELESS DOOR LOCK CONTROL SYSTEM  REGISTRATION  


PROCEDURE

Hide 1. REGISTER RECOGNITION CODES

HINT:
·

Recognition code registration is necessary when the door control transmitter or the door control receiver is replaced with a new one.

·

When registering new recognition codes, the previously registered code are erased. Register the codes of all transmitters you will use.

·

The registration procedure described on the following pages must be performed in order.



a.

Check that the following conditions are met.

·

No key is in the ignition key cylinder.


·

The door control receiver connector or battery negative(-) terminals is disconnected.



b.

Reconnect the door control receiver connector or battery negative(-) terminal.


c.

Perform the following operations within 15 seconds.

i.

Close all doors.


ii.

Press and hold the UNLOCK switch for 5 seconds or more.

B297550
0.406,0.073 5.073,0.698 4.667,0.625 12 Response to registration mode (power door lock operation): 0.406,0.427 5.906,1.031 5.5,0.604 10 Door control receiver automatically performs power door LOCK-UNLOCK operation. 0.438,0.865 2.51,1.427 2.073,0.563 10 LOCK-UNLOCK Occurs Once 1.26,1.583 2.115,1.969 0.854,0.385 10 1 second 0.615,1.99 1.458,2.344 0.844,0.354 10 LOCK 0.427,2.313 1.344,2.667 0.917,0.354 10 UNLOCK

HINT:

If the LOCK-UNLOCK operation is not performed, registration of the recognition code has failed. Repeat the registration procedure from the beginning.




d.

Perform the following operations within 5 seconds.

i.

Press and hold the UNLOCK switch for 1 second or more.

B297550
0.406,0.073 3.417,0.719 3.01,0.646 12 Response to registration mode: 0.406,0.427 5.896,1.021 5.49,0.594 10 Door control receiver automatically performs power door LOCK-UNLOCK operation. 0.438,0.865 2.76,1.51 2.323,0.646 10 LOCK-UNLOCK Occurs Once 1.26,1.583 2.229,2.104 0.969,0.521 10 1 second 0.615,1.99 1.438,2.385 0.823,0.396 10 LOCK 0.427,2.313 1.417,2.656 0.99,0.344 10 UNLOCK

HINT:

If the LOCK-UNLOCK operation is not performed, registration of recognition code has failed. Repeat the registration procedure from the beginning.




e.

If multiple transmitters need to be registered, repeat the registration of a new recognition code procedure within 15 seconds of the previous registration.


f.

If 15 seconds or more elapse after code registration, the registration mode will end.


g.

Registration of the recognition codes is completed.